Download Print this page
AMX FG2263-03 Installation Manual

AMX FG2263-03 Installation Manual

Control phone interface

Advertisement

Quick Links

Overview
The NXV-CPI (FG2263-03) is a small rack-mountable device which enables
users to connect a Cisco IP phone to a NetLinx master to provide room control
from the phone. The NXV-CPI is installed to the NetLinx Master, and passes
NetLinx control commands to the Master via Ethernet 10/100 cable.
FIG. 1
NXV-CPI (front panel)
Specifications
The following table lists the specifications for the NXV-CPI:
NXV-CPI Specifications
Front Panel
• 4 LED Indicators:
Components:
Power LED (green): Solid on indicates power is on.
Status LED (green): Blinks to indicate that the unit is
communicating with the NetLinx Master.
• Output LED (red): Lights to indicate the device is sending an
XML file to the IP phone or a button press to the NetLinx
master.
• Input LED (yellow): Lights to indicate the device is receiving a
command from the NetLinx master or a button press HTTP
message from the IP phone.
• 1 pushbutton for factory default configuration reset
Rear Panel
1 LAN Port - 10/100 Ethernet with PoE. LEDs show
Connectors:
communication activity, connection status, speeds, and mode
information:
• SPD (speed) - Yellow LED lights On when the connection
speed is 100 Mbps and turns Off when the speed is 10 Mbps.
• L/A (link/activity) - Green LED lights On when the Ethernet
cables are connected and terminated correctly, and blinks
when receiving Ethernet data packets.
Power
PoE powered – no local Power Supply needed
Requirements:
Memory:
• 64 Mbytes of RAM
• 256 Mbytes of FLASH
Dimensions
With feet:
(HWD):
• 1.66" x 5.54" x 4.10" (4.216 cm x 14.07 cm x 10.42 cm)
Without feet:
• 1.52" x 5.54" x 4.10" (3.861 cm x 14.07 cm x 10.42 cm)
Weight:
1.45 lbs. (0.65 kg)
Operating
• Operating Temperature: 32°F - 104°F (0°C - 40°C)
Environment:
• Storage Temperature: 14°F - 158°F (-10°C - 70°C)
• Relative Humidity: 5% to 85% non-condensing
• Intended for indoor use only
Other AMX
• PS-POE-AF PoE Injector (FG423-80)
Equipment:
• AC-DIN-CS3 DIN Rail Mounting Bracket (FG532-01)
• AC-RK Accessory Rack Kit (FG515)
Certifications:
• FCC Class B
• CE
• IEC60950
• RoHS
NXV-CPI
Installation
Note: To avoid any damage to the electronic component, installation must be
performed in an ESD safe environment.
The NXV-CPI is installed to the NetLinx Master, and passes NetLinx control
commands to the Master via Ethernet 10/100 cable, as indicated in FIG. 2.
NXV-CPI
PoE injector
FIG. 2
NXV-CPI Installation
Ethernet 10/100 Base-T RJ-45 Wiring Configuration
The table below describes the pinouts, signals, and pairing for the Ethernet
10/100 Base-T connector and cable.
Ethernet Pinouts and Signals
Pin
Signals
Connections
1
TX +
1 --------- 1
2
TX -
2 --------- 2
3
RX +
3 --------- 3
4
no connection
4 --------- 4
5
no connection
5 --------- 5
6
RX -
6 --------- 6
7
no connection
7 --------- 7
8
no connection
8 --------- 8
FIG. 3 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector
and cable.
FIG. 3
Straight-Through Wiring
PoE (Power Over Ethernet)
The NXV-CPI uses CAT5/CAT6 wire via the Ethernet port for PoE power. The
maximum power draw for the NXV-CPI is 2.2 watts.
Use the PS-POE-AF Power over Ethernet Injector (FG423-80) to simplify wiring
and installation by eliminating the need for an AC outlet at each point of
installation.
Note: The NXV-CPI can be placed up to approximately 330' (100 meters) from
the nearest PoE Injector.
If used with a non PoE-capable Ethernet switch, then an optional
PS-POE-AF Power-over-Ethernet (PoE) power supply is required to
provide power to the NXV-CPI.
If the NXV-CPI is used with a PoE-capable Ethernet switch, then no PoE
Injectors are required.

Installation Guide

Control Phone Interface
NetLinx Master
Ethernet 10/100
Ethernet Switch
Ethernet 10/100
To Cisco Call Manager
Pairing
1 --------- 2
White-Orange
Orange
3 --------- 6
White-Green
White-Blue
White-Brown
To Cisco
Phone
Color
Blue
Green
Brown

Advertisement

loading

Summary of Contents for AMX FG2263-03

  • Page 1: Installation Guide

    Installation Note: To avoid any damage to the electronic component, installation must be The NXV-CPI (FG2263-03) is a small rack-mountable device which enables performed in an ESD safe environment. users to connect a Cisco IP phone to a NetLinx master to provide room control The NXV-CPI is installed to the NetLinx Master, and passes NetLinx control from the phone.
  • Page 2: Additional Documentation

    ©2011 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without notice at any time. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com...

This manual is also suitable for:

Nxv-cpi