Item
Condition
Panel tuning mode
[P25
1) Adj item:
(C4FM)]
[P1 SQL]
Adjust:[***]
2) Adj item:
[700M RX/TA
Low]→
[700M RX/TA
Center]→
[700M RX/TA
High]→
[800M RX/TA
Low]→
[800M RX/TA
Ceter]→
[800M RX/TA
High]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 1kHz/
±2.2kHz)
[P25
1) Adj item:
(LSM)]
[P1 SQL]
Adjust:[***]
2) Adj item:
[700M RX/TA
Low]→
[700M RX/TA
Center]→
[700M RX/TA
High]→
[800M RX/TA
Low]→
[800M RX/TA
Ceter]→
[800M RX/TA
High]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3.3kHz)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
SSG
[Open Squelch
Distor-
(P25 C4FM)]
tion
2) Adj item:
meter
[Frequency:
Oscillo-
700 MHz Band]
scope
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Ceter]→
[RX/TA High]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 1kHz/
±2.2kHz)
1) Adj item:
SSG
[Open Squelch
Distor-
(P25 LSM)]
tion
2) Adj item:
meter
[Frequency:
Oscillo-
700 MHz Band]
scope
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Ceter]→
[RX/TA High]
SSG output:
12dB SINAD level at
Analog Narrow
-3dB
(MOD: 1kHz/
±3.3kHz)
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel
Ext.
SP
con-
nector
Panel ANT
Panel
Ext.
SP
con-
nector
Adjustment
Method
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
(No.RA032<Rev.001>)1-71
Specifi-
cations
/Remarks