Kenwood NX-5900 Service Manual page 47

700/800mhz digital transceiver
Hide thumbs Also See for NX-5900:
Table of Contents

Advertisement

4.8
Common Section
Item
Condition
Panel tuning
mode
1.
1) DC voltage:13.6V
Setting
2) SSG standard modulation
[Wide 5k] MOD:1kHz,DEV:3kHz
[Wide 4k] MOD:1kHz,DEV:2.4kHz
[Narrow] MOD:1kHz,DEV:1.5kHz
2.
1) Adj item:
1) Adj item:
Receive
[RAST]
Assist
Adjust:[****]
2) Adj item:
2) Adj item:
[700M RX/
TA Low]→
[700M RX/
TA High]→
[800M RX/
TA Low]→
[800M RX/
TA High]
Adjust:[****]
Press [
]
key to store
the adjust-
ment value.
3.
1) Adj item:
1) Adj item:
Transmit
[TAST]
Assist
Adjust:[****]
2) Adj item:
2) Adj item:
[700M RX/
TA Low]→
[700M RX/
TA High]→
[700M TX
Low]→
[700M TX
High]→
[800M TX
Low]→
[800M TX
High]→
[800M RX/
TA Low]→
[800M RX/
TA High]
Adjust:[****]
PTT: ON.
Press [
]
key to store
the adjust-
ment value.
Measurement
PC test mode
Test-
equip-
ment
[Receive Assist]
[Frequency:
700MHz Band]
[RX/TA Low]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA High]
Press [Apply All]
button to store the
adjustment value.
[Transmit Assist]
[Frequency:
700MHz Band]
[RX/TA Low]→
[RX/TA High]→
[TX Low]→
[TX High]
[Frequency:
800MHz Band]
[TX Low]→
[TX High]→
[RX/TA Low]→
[RX/TA High]
PTT Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Adjustment
Unit
Ter-
Unit
Parts
minal
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Panel [Panel
tuning
mode]
[ ],
[ ]
[PC
test
mode]
[←],
[→]
Specifications
Method
[PC test mode]
2.5V±0.1V
[Automatic
[Automatic
Adjustment]
Adjustment]
1) Press [Tune Assist
After the automatic
Voltage] button.
adjustment is per-
2) Press [Apply All] but-
formed, verify that
ton to store the adjust-
the VCO lock volt-
ment value after the
age is within the
automatic adjustment
voltage range
has finished.
which is specified
[Manual Adjustment]
by the manual ad-
[V] indicator on the PC
justment.
window shows VCO lock
[Manual Adjust-
voltage. Change the ad-
ment]
justment value to get
Press [Apply All]
VCO lock voltage within
button to store the
the limit of the specified
adjustment value
voltage.
after all adjustment
point have been
Note:
adjusted.
Confirm the VCO lock
voltage approximately
Note:
3 seconds after the
The assist adjust-
adjustment value is
ment value must
changed.
be between from
340 to 3550.
(No.RA032<Rev.001>)1-47
/Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-5900b

Table of Contents