Kenwood NX-5900 Service Manual page 69

700/800mhz digital transceiver
Hide thumbs Also See for NX-5900:
Table of Contents

Advertisement

4.10 Receiver Section
Item
Condition
Panel tuning mode
1.
[Panel test mode]
AF level
1) CH-Sig: 1-1
setting
SSG output:
-47dBm (1mV)
(MOD: 1kHz/
±1.5kHz)
2. RSSI
1) Adj item:
refer-
[An RRSSI]
ence
Adjust:[***]
[Analog
2) Adj item:
Narrow]
[700M RX/TA
Low]→
[700M RX/TA
Center]→
[700M RX/TA
High]→
[800M RX/TA
Low]→
[800M RX/TA
Ceter]→
[800M RX/TA
High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±1.5kHz)
3. Open
1) Adj item:
Squelch
[Aw SQL]
[Analog
Adjust:[***]
Wide
2) Adj item:
5k]
[700M RX/TA
Low]→
[700M RX/TA
Center]→
[700M RX/TA
High]→
[800M RX/TA
Low]→
[800M RX/TA
Ceter]→
[800M RX/TA
High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±3kHz)
Measurement
PC test mode
Test-
equip-
ment
1) Test Channel
SSG
Channel: 1
DVM
Test Signaling
AF VM
Mode: Analog
Dummy
Signaling: 1
load
SSG output:
-47dBm (1mV)
(MOD:1kHz/
±1.5kHz)
1) Adj item:
SSG
[RSSI Reference
Distor-
(Analog Narrow)]
tion
2) Adj item:
meter
[Frequency:
Oscil-
700 MHz Band]
loscop
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Ceter]→
[RX/TA High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
SSG
[Open Squelch
Distor-
(Analog Wide 5k)]
tion
2) Adj item:
meter
[Frequency:
Oscil-
700 MHz Band]
loscop
[RX/TA Low]→
[RX/TA Center]→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]→
[RX/TA Ceter]→
[RX/TA High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/±3kHz)
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
Ext.
tuning
SP
mode]
con-
[+], [-]
nector
[PC
test
mode]
[←],
[→]
Panel ANT
Panel
Ext.
SP
con-
nector
Panel ANT
Panel
Ext.
SP
con-
nector
Adjustment
Method
Volume Up/Down knob to
obtain 1.41V AF output.
(0.5W @ 4Ω load)
[Panel tuning mode]
After input signal from
SSG, press [
key to
store the adjustment val-
ue.
PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
(No.RA032<Rev.001>)1-69
Specifi-
cations
/Remarks
1.41V
±0.1V

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-5900b

Table of Contents