View Smbios Event Log - Supermicro X10DRT-B+ User Manual

Table of Contents

Advertisement

X10DRT-B+ Motherboard User's Manual
When Log is Full
Select Erase Immediately to immediately erase all errors in the SMBIOS event log
when the event log is full. Select Do Nothing for the system to do nothing when
the SMBIOS event log is full. The options are Do Nothing and Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Disabled and Enabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between
1 to 255. The default setting is 1.
METW (Multiple Event Count Time Window)
This item is used to determine how long (in minutes) should the multiple event
counter wait before generating a new event log. Enter a number between 0 to 99.
The default setting is 60.
Note: Please reboot the system for the changes to take effect.

View SMBIOS Event Log

This item allows the user to view the event in the SMBIOS event log. Select this
item and press <Enter> to view the status of an event in the log. The following
categories are displayed:
Date
Time
Error Code
Severity
4-32