5.3
This allows the user to arm the perimeter zones while disabling the interior zones so that it is possible to
remain on the premises. If zones are likely to be violated accidentally, they should be programmed as
BUZZ zones (refer to page 19). The panel can be programmed with two different STAY PROFILES to be
used as required. Following is an example of where this may be used. Assume a property has perimeter
sensors to secure a garden fence and a number of internal sensors within each room of the house.
The first STAY PROFILE would function as follows: At night while you are within the house going about
your normal evening activities it may be desirable to activate the alarm such that any violation of the
perimeter sensors will cause an alarm. Therefore, this profile would have all internal sensors programmed
as STAY zones (bypassed) and perimeter sensors would be normal alarm zones.
A second STAY PROFILE would then be utilised once the family retires to their bedrooms. All bedrooms
would therefore be STAY zones (bypassed) while unused zones i.e. a lounge and TV room, together with
perimeter zones would be normal alarm zones.
NOTE:
Once a particular stay profile is selected, the system will use the selected profile each time the system is
armed into the STAY MODE. If the alternate profile is required, it is necessary to select the alternate
profile before the system is armed.
The arming procedures and quick keys will have effect on the selected profile. STAY and BUZZ zones
can be programmed for each profile once the profile has been entered.
5.3.1
1.
Press the [#] key to clear any previous entries.
2.
Press [MODE].
3.
Press [9] then press [1] or [2] for the required profile.
4.
Press [*] to enter. A long beep should be heard.
5.
Program STAY and BUZZ zones for the profile or ARM the profile (See sections 12 and 13).
5.3.2
1.
Select the required STAY PROFILE.
2.
Ensure that the READY indicator is on; if not, check that all protected doors and windows are
closed and that motion has ceased in the areas covered by motion detectors.
3.
If necessary, close the front door.
4.
Press the [#] key to cancel any unintended entries.
5.
Enter a valid [USER CODE].
6.
The ARMED indicator will come on and the keypad buzzer will sound on and off for the duration
of the exit delay.
7.
DO NOT open the front door. If the front door is opened, the system will arm in AWAY mode.
8.
The AWAY indicator will remain off.
9.
Any STAY zones (shown by a steadily lit indicator) will be automatically bypassed.
10.
Ensure that you enter only those zones that are bypassed.
12
To Enter a Stay Profile
[#] + [MODE] + [9] + [PROFILE NUMBER] + [*]
[#] + [USER CODE]
(Do not leave premises)
IDS 805 User Manual 700-266-01C Issued March 2009
Stay Arming
To Stay Arm