X1R Smart – User Manual
1
Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk

Advertisement

Table of Contents
loading

Summary of Contents for Iseo X1R Smart

  • Page 1 X1R Smart – User Manual Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 2 Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 3: About This Manual

    The door is equipped with an electronic lock with a motor-driven bolt closing mechanism with built- in digital control. ISEO research and experience have led to the development of a product that offers the state of the art in terms of security and reliability. To find out all about this product and make the best use of all it has to offer, read this booklet and keep it handy.
  • Page 4: Information On Copyright

    • Door contact sensor: electronic device made of 2 contacts and installed in the door frame, that allows X1R Smart to know if door is ajar or open. It is possible to install it in the lock side or in the hinges side of the door.
  • Page 5 Door fully open: spring latch and bolts backward/withdrawn. • Door status relay: it is a relay, built-in into the X1R Smart electronic board, that allows to send outside the Door status signal: open or close. It can be used for example in a home automation system, to switch on the light when door opens, or to activate an alarm system when door closes.
  • Page 6: Table Of Contents

    13 Options and versions 17 Electrical connections Maintenance 19 Example of 8 Pins Multifunction Cable wiring scheme 51 Battery replacement 53 Notes on battery usage by X1R Smart Getting Started 54 Cleaning 54 Storage 20 Package contents 20 Product identification...
  • Page 7: Safety And Environment

    • Preserve this manual as future reference. • The installation of the device requires the intervention of qualified staff, adequately trained by ISEO. • The instructions should be carefully followed during installation. These instructions and any maintenance instructions should be passed on by the installer to the user.
  • Page 8: Disposal And Recycling

    Sicurezza e ambiente • The X1R Smart lock works correctly when using cylinders with standardised profile cams of the size indicated below: • When used with cylinder with knobs, make sure that after the cylinder has been turned the cam does not remain engaged, which will cause the motor to rotate in neutral.
  • Page 9: Overview

    Overview What is X1R Smart X1R Smart is the utmost evolution of X1R Easy, the electronic motorized lock for armored doors, developed and created by ISEO for the electronic access control. X1R Smart embed a Bluetooth Smart multistandard ISO 14443 A/B reader, in order to work with Argo, the new application suitable for Android and iOS smartphone.
  • Page 10: System Components

    Master Card (system’s initialization and plant code assignment)  Mifare cards/tags RFID credentials  ISEO cards/tags  Bluetooth 4.0 ready  From iPhone 4s with iOS 7 and above Smartphone with app Argo  Android phones from ver. 4.3 External control module: external keyboard with ...
  • Page 11: Technical Data

    Overview Technical data Features Description  Multistandard 13,56 Mhz RFID Reader  ISO14443A/ ISO14443B (Mifare Classic/Plus/DesFire).  2,4GHz Radio Board Bluetooth 4.0 Module  Power supply unit 8-30Vdc, P = 30W Power Supply  6 x 1,5V Alkaline Batteries “D” Type ...
  • Page 12: Dimensions

    Overview Dimensions Feature Dimensions  8mm Handle follower  63mm Backset  85mm Centre distance For detailed commercial information, please check X1RSmart catalogue and leaflet available at link: http://gamma.iseozero1.com/en/serrature-elettroniche/ Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 13: Options And Versions

    Overview Options and versions There are several possible configurations and options available. Each configuration can be Standard or Single Action version, with battery, DC power or both. DC power can be supply via concealed cable gland spring or door sensor contacts. You can decide to install only an external RFID reader or keyboard option too.
  • Page 14 Overview A. Alkaline batteries powered. No wiring needed. The lock uniquely works by using the alkaline battery pack. X1R Smart lock. Two buttons internal control module (not necessary if Single Action version). Alkaline batteries (6x1,5V “D” type). Battery holder. External control module: keyboard and RFID reader or only RFID reader without keyboard. It embeds the Bluetooth radio module.
  • Page 15 Power is supplied by an external feeder connected to the mains. Power cable reach the lock through the cable gland spring usually placed in the hinges side of the door. X1R Smart lock. Two buttons internal control module (not necessary if Single Action version).
  • Page 16 When the door is opened power supply is provided by alkaline batteries, which also act as a back-up in case of power failure. X1R Smart lock. Two buttons internal control module (not necessary if Single Action version). Alkaline batteries (6x1,5V “D” type).
  • Page 17: Electrical Connections

    Overview Electrical connections The Relay normally closed contact, is intended with door closed and safe (bolts extended). Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 18 Overview See below a real picture of the lock, with the electrical connections in the standard configuration and connectors’ description. JP1 connector Batteries power supply cable 2 Buttons internal control module External control module: keyboard cable and/or RFID reader. Door sensor contact connector if installed in the door hinges side.
  • Page 19: Example Of 8 Pins Multifunction Cable Wiring Scheme

    Overview Example of 8 poles Multifunction Cable wiring scheme See below a connection example related to the following specifications:  External power supply by cable gland spring.  Relay outputs connected to 2 lights, green and red, to show the door status: o NC output connected to green light (door closed and safe);...
  • Page 20: Getting Started

    Getting Started Package contents The product box contains the following items: 1. X1R Smart electronic motorized lock 2. Door contact sensor 3. Plug for handle follower hole (to be used only for Single Action version) 4. Cylinder fixing screws kit (2 different screws) 5.
  • Page 21 Getting started Product codification Product code is composed as follows: 00069X XX XX 050 9 = Single Action Pistons Pistons center 6 = Standard projection (mm) distance (mm) with faceplate Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 22: Installing X1R Smart

    This operation, that keeps about 50 seconds, is indicated to the user by the orange led, in the external module, continuously flashing. Do not switch off X1R Smart during this operation and do not press any button or disconnect any cable, in order to avoid device malfunctions.
  • Page 23 The use of Master cards 2 and 3 will be required only if Master Card 1 is lost or damaged. All X1R Smart belonging to the same plant must be initialized or updated with the same Master Card.
  • Page 24: Add Credentials Without Argo App

    Getting started Add credentials without Argo App You can add credentials, such as Mifare cards or tags, using the Master Card and the RFID reader placed in the external control module. 3. Read the Cards to add to the User List. 1.
  • Page 25: Add Pin Code Without Argo App

    Getting started Add a PIN code without Argo app You can add one or more codes to open, using the Master Card and the external keyboard. 1. Present the Master Card 1 to the 3. Enter your PIN code, from 4 to 14 characters, device to enter in Programming Mode.
  • Page 26 1. Download the free Argo ISEO application from the APP Store (iOS) or Google Play (Android). 2. Enable Bluetooth communication on your smartphone. 3. Open the Argo app. You will see in the smartphone display, into a ray of 10mt, the X1R Smart icon/button, identified by its serial number.
  • Page 27 Bluetooth pairing is not more necessary starting from software version MH0YX133, included into Argo 2.1 To know more about pairing and in-app pairing technology, read the Argo User Manual available at: https://app.iseo.com Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 28 User List on your smartphone. The last memorized credential is displayed on the top of the list. Added phone Added Mifare and ISEO cards or tag Users menu Door Info menu Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 29 9. Go back to Users menu and then tap < Argo on the top left corner, to go out Programming Mode. 10. Press the X1R Smart icon button to open by your phone. Alternatively, read the cards or tags previously memorized.
  • Page 30: Swissdoor Aps, Stenhuggervej 2, Dk-5471 Soendersoe, Tlf.: +45 86 28 00 00, Mail@Swissdoor.dk, Www.swissdoor.dk

    Getting started Adding a PIN code by Argo app You can memorize one or mode PIN code to open, by using the Argo app and the external numeric keypad. 1. Present Master Card 1 to the reader to enter Programming Mode. The icon in the app become red.
  • Page 31: Swissdoor Aps, Stenhuggervej 2, Dk-5471 Soendersoe, Tlf.: +45 86 28 00 00, Mail@Swissdoor.dk, Www.swissdoor.dk

    Events, nor in the Dump Information. To know more about VIP and Block Standard User function and Dump Information, refer to Argo User Manual, available at link: https://app.iseo.com Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 32: Basics

    From the external door side, in the standard configuration, you can open the door in the next ways: 1. Using your smartphone and the Argo app. 2. Using an authorized ISEO or Mifare card/tag, reading it by means of the external control module (with keyboard or RFID reader only).
  • Page 33 INTERNAL SIDE 3. Single Action version In case of electronic or power supply issues, X1R Smart can always be opened, from the internal and the external side, by the mechanical key. Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 34: Door Info Menu

    Then press Door Info icon in the bottom bar. In this menu, you can change the door name as previously seen, and you can see some more information about X1R Smart. It shows the battery charge status or a lightning icon, in case of external power supply.
  • Page 35: Advanced

    Passage Mode, following a power OFF, will restore automatically the Passage Mode function when ON again. You can disable or enable all X1R Smart sounds. When off the lock will not emit any sound. For information, refer to the Argo User Manual at link: https://app.iseo.com...
  • Page 36: Reset

    Advanced It allows you to select a different functioning mode. To know more about this function go to Functional Mode paragraph. It is the elapsing time between the door closing and the bolts locking. It allows you to differently configure the internal relay behavior.
  • Page 37: Versions

    Versions menu shows the serial numbers and the software versions of all the electronic boards composing X1R Smart. Main electronic board Serial number. X1R Smart main board software. This is the most important software version, upgradeable via Argo app. Bluetooth radio module software version.
  • Page 38: Functional Modes

    Advanced Functional Modes X1R Smart can be configured in 5 different Functional Modes, that can be activated or deactivated by the Argo app. The standard factory configuration is Mode 1. In this mode the lock will automatically shoot the bolts at every closing (maximum security).
  • Page 39 Advanced Below a complete description of the 5 Functional Modes. Mode Description The lock withdraws bolts and latch when opening and automatically shoot the bolts when closing. Standard mode. Maximum security. The lock withdraws only the bolts when opening and automatically shoot the bolts when closing.
  • Page 40: Door Status Relay

    Advanced Door status relay The output relay, embedded into the X1R Smart electronic board, allows you to get as standard output the Door status: open or closed. When the door is closed and safe, the relay is not active. When the door opens the relay become active, changing its internal state: the normally closed contact (NC), opens, while the normally open (NO), closes.
  • Page 41 Advanced If the value is not 0, the output relay provides, when opening, a single pulse with duration equal to the value set in milliseconds. The maximum programmable value is 1000msec (1sec.). This solution is suitable for example, to drive an automatic swing door operator. In this case, in fact, it is necessary to send a single pulse to start the swing door operator.
  • Page 42: Remote Opening Command

    Advanced Remote opening command The X1RSmart electronic motorized lock, even provides an optoisolated input embedded into the electronic board. This input allows to connect a remote opening command, that can be, for example, the intercom button or a push button located in the reception or concierge table. This command can also be sent by an external control unit, belonging to an home automation system, alarm system or centralized opening system.
  • Page 43: Door Contact Sensor

    Door contact sensor The door contact sensor allows X1R Smart to define is the door is open or ajar. It is an electronic device composed by 2 contacts and installed in the fixed door frame, in the lock side. When the door is ajar the 2 contacts touch other 2 contacts, with adjustable spring, located inside the X1R Smart, in order to indicate to the electronic of the lock that door is actually ajar.
  • Page 44 To be connected to X1R Smart. This new sensor, provided with cable, has to be connected to a 2 pin dedicated connector, placed into the X1R Smart electronic board (see Electrical connection paragraph). Female door contact sensor: to get the door “ajar status”. It is possible to...
  • Page 45: Wiring Specifications

    Advanced Wiring specifications In the next table you can find the wiring specifications in relation to the power supply voltage and the distance between power supply and lock. Lock and power Minimum power supply Minimum wire gauge (mm ) in Wiring supply maximum (Vdc)
  • Page 46: Events Log Messages

    Per gli altri messaggi dello storico eventi relativi all’app Argo e comuni a tutti i dispositivi della serie Smart, consulta il paragrafo Messaggi dello storico eventi nel Manuale Utente Argo al link: https://app.iseo.com Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 47: X1R Smart As Actuator

    Advanced X1R Smart as actuator The X1R Smart electronic motorized lock, can be also used as a simple actuator. In other words as a device that act an opening or closing action, following an external control signal (remote opening command).
  • Page 48 Advanced To use the X1R Smart as actuator it is necessary to fit the jumper, available in the package, in the connector named JP1, as shown in the following picture. To use the lock as actuator, fit the jumper in the first top position...
  • Page 49 Advanced When the X1R Smart is configured as actuator, it is not possible to interact with Argo app and your smartphone, loosing as a matter of fact, all functions related to Argo, including:  The functional mode changing (go to paragraph Functional Modes);...
  • Page 50: More Advanced Function About Argo App

    Advanced More advanced function about Argo app To know more advanced functions about Argo app, read the Argo User Manual available at: https://app.iseo.com You can find explained the next important functions:  Battery levels  Software upgrade  Updating of Master Card level ...
  • Page 51: Maintenance

    Maintenance Battery replacement At every opening of X1R Smart by your smartphone, the button shows the battery level icon. Battery level icon: there are 4 battery levels. The battery level is also shown in the Door Info menu. At the first battery low signal, replace the battery as soon as possible.
  • Page 52 Manutenzione To replace the batteries proceed as follows: 1. Find the battery pack position. This depends on door manufacturer. Usually it is installed in the front side of the door, up or down. In other cases, it can be placed in the top side of the door or even in the hinge side.
  • Page 53: Notes On Battery Usage By X1R Smart

    Manutenzione Notes on battery usage by X1R Smart When X1R Smart is not powered only by batteries, but also by external power supply unit, by cable gland spring or door sensor contacts, the batteries level behavior changes depending on configuration type (see paragraph Options and versions). To know in advance when battery need to be replaced, in order to avoid malfunction issues due to low or expired batteries, read the next information related to the 3 main configurations.
  • Page 54: Cleaning

    Storage  If X1R Smart will not be used for an extended period, remove the battery, and store the battery in a cool, dry area, taking care that terminals doesn’t touch any conductive object or part.  Store X1R Smart in a clean dry place at a room temperature between -25°C and +65°C and relative humidity between 20% and 95%, without condensing.
  • Page 55: Troubleshooting

    Troubleshooting Argo app error messages For those information refer to the Argo User Manual available at: https://app.iseo.com X1R Smart troubleshooting Issue Possible cause Possible solution  Check the cylinder cam is in right internal motor The motor cannot engage the sounds like “free rotating”.
  • Page 56 Troubleshooting Issue Possible cause Possible solution  Check if Functional Mode 5 is enabled. X1R does not respond to any X1R can be in Functional command. Latch and bolts Mode 5 with bolts out. If yes withdrawn the bolts by doesn’t move.
  • Page 57 Troubleshooting Issue Possible cause Possible solution  Disattivare la funzione Blocco Utenti Le credenziali abilitate non Funzione Blocco Utenti aprono. Il lettore emette 2 Standard attiva. Standard con app Argo. segnalazioni acustiche unite a 2 lampeggi rossi.  Sostituire le pile con nuove. Appena apro la porta la Alimentazione sensore...
  • Page 58: Light And Acoustic Signal

    Troubleshooting Light and acoustic signal Light & acoustic signal Meaning Notes First X1R Smart switch on: X1R Smart updates the control modules, updating external including the Bluetooth module. Do not internal control modules. switch off the lock during this operation.
  • Page 59: Technical Assistance

     Argo app software version.  Smartphone model and software version.  X1R Smart configuration and main board software version.  Precise and detailed description of the issue. Swissdoor ApS, Stenhuggervej 2, DK-5471 Soendersoe, Tlf.: +45 86 28 00 00, mail@swissdoor.dk, www.swissdoor.dk...
  • Page 60 Danish seller: Swissdoor ApS Stenhuggervej 2 DK-5471 Soendersoe Tlf.: +45 86 28 00 00 mail@swissdoor.dk www.swissdoor.dk...