Setting Master / Slave Mode; Dmx Protocol; 1 Channel Mode:; 2 Channel Mode: - Lightmaxx COMPLETE PAR 56 User Manual

9x 12 watt rgbaw-uv
Hide thumbs Also See for COMPLETE PAR 56:
Table of Contents

Advertisement

Available languages

Available languages

Setting Master / Slave mode:

When the display shows:
S L A V E
M O D E
It is the slave setting and will run after the master unit.

DMX Protocol:

Press MODE button until the display shows Addr, you can now set the desired
address via UP / DOWN buttons.
The device has 9 DMX modes as following:

1 channel mode:

Channel:
1

2 channel mode:

Channel:
1
2
3 channel mode:
Channel:
1
2
3
4 channel mode:
Channel:
1
2
3
4
Value:
000-255
Value:
000-255
000-255
Value:
000-255
000-255
000-255
Value:
000-255
000-255
000-255
000-255
9
Function:
R+G+B+W+A+UV (0-
100%)
Function:
R+G+B+W+A+UV (0-
100%)
Strobe (0-100%)
Function:
Red (0-100%)
Green (0-100%)
Blue (0-100%)
Function:
Red (0-100%)
Green (0-100%)
Blue (0-100%)
White (0-100%)