Electrical
Table 6
TABLE 6
Dimension
DC input
Power consumption
Architectural specification
The 8/4Gbps FC SAN Module meets the specifications shown in
TABLE 7
Feature
NPIV logins per port
NPIV login per Module
Performance
Fabric latency
(Fabric OS Native mode only)
Maximum frame size
Class of service
Port types
Supported HBAs
For more information and a list of supported HBAs, refer to your Dell PowerEdge documentation.
Dell 8/4Gbps FC SAN Module Hardware User's Manual
53-1001964-01
lists FC SAN Module electrical specifications.
Electrical specifications and requirements
Measurements
12 V and 3.3 V from chassis
About 32 W normally and 39 W maximum measured
Architecture
Description
Max: 254, Default: 126
Max: 2032, Default: 384.
1.063 Gbps line speed, full duplex
2.125 Gbps line speed, full duplex
4.25 Gbps line speed, full duplex
8.50 Gbps line speed, full duplex
<0.7 sec with no contention
2112-byte payload
Class 2
Class 3
FL_Port
F_Port
N_Port
Electrical
Table
7.
A
29