Summary of Contents for Vivreau V3-203

  • Page 1 Freshly-drawn Traditionally Served Environmentally Friendly Specially Branded Owner’s Manual V3 Dispensing System MODEL V3-203 170207...
  • Page 2 This manual and all material provided with your system should be retained in a convenient location for future reference. Contact Vivreau if you have any questions regarding the information contained in this manual. © 2017 Vivreau USA All rights reserved.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SAFETY PRECAUTIONS ............5 GENERAL INFORMATION ............7 TECHNICAL SPECIFICATIONS ..........9 PRE-INSTALLATION REQUIREMENTS ........11 OPERATING INSTRUCTIONS ..........13 MAINTENANCE ................17 TROUBLESHOOTING ...............23 V3-203 Dispensing System Owner’s Manual...
  • Page 4 V3-203 Dispensing System Owner’s Manual...
  • Page 5: Safety Precautions

    Save these instructions. • plumbing and refrigeration technicians should service this unit. WARNING ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE. V3-203 Dispensing System Owner’s Manual 5...
  • Page 6 Section 1 Safety Precautions V3-203 Dispensing System Owner’s Manual...
  • Page 7: General Information

    This manual is solely for the use of personnel the Vivreau V3-203 Dispensing System. trained in the operation of the Vivreau V3-203 Dispensing System only. • Information contained in this manual will help prevent risks to health and safety, and the risk of economic losses.
  • Page 8 Section 2 General Information V3-203 Dispensing System Owner’s Manual...
  • Page 9: Technical Specifications

    Chilled Water on demand. and selection is based on space available for installation. There are two (2) orientations of the Vivreau V3-203 Dispensing System; Model V3-203A incorporates a The system has been designed for operation at horizontal Chiller and Model V3-203B incorporates ambient temperatures up to 90ºF .
  • Page 10 Section 3 Technical Specifications 10 V3-203 Dispensing System Owner’s Manual...
  • Page 11: Pre-Installation Requirements

    " Vivreau V3-203 Dispensing System PRE-INSTALLATION Below are the services required to be in place prior to the installation of the Vivreau V3-203 Dispensing System. If you have any questions regarding these or other services, please contact " Vivreau Service Toll-Free at 877-999-1044.
  • Page 12 Ventilation can be made through the base of the cabinet, with the removal of a narrow section of floor immediately behind the door. Trim with roll edging strip. Cut-out size must not be less than 11.0" wide x 1.5" deep. Ventilation Options 12 V3-203 Dispensing System Owner’s Manual...
  • Page 13 90°F. IMPORTANT _________________________ The Vivreau V3-203 Dispensing System should not be exposed to spills, spray, steam or high humidity. Installation must be performed by properly A suitable location should be chosen within 40”...
  • Page 14 Section 4 Pre-Installation Requirements 14 V3-203 Dispensing System Owner’s Manual...
  • Page 15: Operating Instructions

    Bottle at a time. The Dispenser Handle must be closed after each Bottle is filled. Vivreau Bottles should be filled to the line in the neck just below the Cap. At the end of service, remove the Black Dispenser Nozzle and soak in Sanitizing Solution.
  • Page 16 ALWAYS use Vivreau Storage and Dishwasher Racks. DO NOT empty into Vivreau V3-203 Dispensing System Drip Tray. Clean Drip Tray New Bottles MUST be sanitized before first use. Once the unit is wiped down and Nozzle ALWAYS inspect Bottles for damage.
  • Page 17 ALWAYS visually inspect Bottles for damage before storing. ALWAYS place Bottles upright in Blue Storage Racks. Storage Racks can be stacked. ALWAYS place plastic film over the top crate to ensure exterior of Bottles are kept clean. V3-203 Dispensing System Owner’s Manual...
  • Page 18 Section 5 Operation 18 V3-203 Dispensing System Owner’s Manual...
  • Page 19: Maintenance

    General check of the unit • Identify and replace worn parts IMPORTANT _________________________ Record all yearly inspections. IMPORTANT _________________________ Contact the factory, the factory representative or an authorized service agent to perform maintenance and repairs. V3-203 Dispensing System Owner’s Manual...
  • Page 20 DAILY CLEANING CAUTION Never use any metal tools. Scrapers, files, wire brushes or scouring pads (except for The Vivreau V3-203 Dispensing System should stainless steel scouring pads) will mar the surface. be cleaned once a day. Vivreau recommends using disinfectant spray CAUTION Never use steel wool, which will or a sanitizing wipe for cleaning.
  • Page 21 Replacement Twice Yearly Dealer CLEANING THE DISPENSER NOZZLE CLEANING THE DRIP TRAY The Vivreau V3-203 Dispensing System is Lift Drip Tray Lid from unit. equipped with a removable Nozzle for ease of cleaning and sanitizing. IMPORTANT _________________________ The Nozzle must be cleaned separately in Sanitizing Solution.
  • Page 22 Never use abrasive cleaners to clean the equipment. V3-203A STANDING IDLE Before Long Idle Periods If the Vivreau V3-203 Dispensing System will be idle for more than 3 days: Unplug the Unit. Close the Water Supply Valve. Clean the following with antibacterial wipes and...
  • Page 23 Water Supply Valve. Clean the following areas with antibacterial Clean up the leaked water from the area. cloths and Sanitizing Spray: Indicate the Vivreau V3-203 Dispensing System • Dispensing Nozzle is out of service by hanging a DO NOT USE •...
  • Page 24 Section 6 Maintenance 24 V3-203 Dispensing System Owner’s Manual...
  • Page 25: Troubleshooting

    Make sure the Condenser Grille is not clogged Always switch OFF and unplug the equipment or blocked. before performing service repair procedures. IMPORTANT _________________________ If these troubleshooting procedures do not resolve the issue, please contact Vivreau Service Toll-Free at 877-999-1044. V3-203 Dispensing System Owner’s Manual...
  • Page 26 Section 7 Troubleshooting NOTES 26 V3-203 Dispensing System Owner’s Manual...
  • Page 27 V3-203 Dispensing System Owner’s Manual...