Step
6.
Assign the port or the range
of ports to the BFD MAD
VLAN.
7.
Return to system view.
8.
Create the VLAN interface
and enter VLAN interface
view.
9.
Enable BFD MAD.
10. Assign a MAD IP address to
each member device on the
VLAN interface.
Configuring BFD MAD that uses management Ethernet ports
When you configure BFD MAD that uses management Ethernet ports, follow these restrictions and
guidelines:
Category
Ports on the intermediate
device for BFD MAD
BFD MAD VLAN
MAD IP address
To configure BFD MAD that uses management Ethernet ports:
Step
1.
Enter system view.
Command
[ to interface-type
interface-number ] } &<1-24>
Enter interface view:
interface interface-type
interface-number
Assign the port to the VLAN as
an access port:
port access vlan vlan-id
Assign the port to the VLAN as a
trunk port:
port trunk permit vlan vlan-id
Assign the port to the VLAN as a
hybrid port:
port hybrid vlan vlan-id
{ tagged | untagged }
quit
interface vlan-interface
vlan-interface-id
mad bfd enable
mad ip address ip-address { mask |
mask-length } member member-id
Restrictions and guidelines
Use common Ethernet ports on the intermediate device to connect to the BFD
MAD-enabled management Ethernet ports on the IRF fabric.
On the intermediate device, create a VLAN for BFD MAD, and assign the
ports used for BFD MAD to the VLAN. On the IRF fabric, you do not need
to assign the BFD MAD-enabled management Ethernet ports to the
VLAN.
Make sure the IRF fabrics on the network use different BFD MAD VLANs.
Make sure the BFD MAD VLAN on the intermediate device contains only
ports on the BFD MAD links. Exclude a port from the BFD MAD VLAN if
the port is not on the BFD MAD link. For example, if you have assigned
the port to all VLANs by using the port trunk permit vlan all command,
use the undo port trunk permit command to exclude the port from the
BFD MAD VLAN.
Use the mad ip address command instead of the ip address command
to configure MAD IP addresses on the BFD MAD-enabled management
Ethernet ports.
Make sure all the MAD IP addresses are on the same subnet.
Command
system-view
27
Remarks
To assign one port to the BFD
MAD VLAN, enter Ethernet
interface view.
The link type of BFD MAD ports
can be access, trunk, or hybrid.
The default link type of a port is
access.
N/A
N/A
By default, BFD MAD is
disabled.
By default, no MAD IP address
is configured for an IRF
member device on a VLAN
interface.
Remarks