Suncourt TW208P Installation Instructions

Room to room fan

Advertisement

READ AND SAVE THESE INSTALLATION INSTRUCTIONS
WARNING - To Reduce The Risk Of Fire Or Electric Shock, Read These Instructions
Before Installing Your Thruwall TW208P Room To Room Fan.
This fan is not to be installed in the ceiling or an outside wall.
This fan is not be used in cooking or damp areas.
Do not install in fire rated walls.
With the use of any electrical appliance, it is important to observe all basic precautions to
minimize the risk associated with use, such as electrical shock, fire, or injury to persons.
If you have doubts or are unfamiliar with this type of installation work, seek the services
of a qualified electrician. Suncourt assumes no responsibility for installation of the
ThruWall Fan. For your safety and protection follow all instructions and adhere to
applicable building and/or electrical codes. Not for bathroom use. Do not use in wet
locations.Do not use in a window.
Warning - To Reduce The Risk Of Fire, Electric Shock Of Injury To Persons, Observe
Installation work and electrical wiring must be done by qualified person (s) in accordance
with all applicable codes and standards, including fire-rated construction. When cutting
or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
Prior to installation of the TW208P fan, switch power off at service panel and lock
service panel to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such
as a tag, to the service panel.
The installation of your ThruWall fan requires that the cutouts must be accurate.
In the carton you will find:
(1) Telescoping metal sleeve with plastic grille attached
(1) Telescoping metal sleeve without grille attached
(1) Loose grille
(1) Template
(7) #6 Screws
(7) Wall Anchors
(3) Wire Nuts
PLEASE READ THESE INSTRUCTIONS BEFORE STARTING INSTALLATION
The ThruWall fan moves air from room to room quietly and efficiently. Installs in any
frame wall from 3-1/2" to 6-1/2" thick. A high quality Thermally Protected motor with
balanced fan blade moves up to 200 CFM. The ThruWall can be mounted in any normal
drywall or paneled stud construction wall up to 6-1/2 " maximum total thickness.
FOR THRUWALL FAN™ Model TW208P
The Following:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TW208P and is the answer not in the manual?

Questions and answers

Summary of Contents for Suncourt TW208P

  • Page 1 Prior to installation of the TW208P fan, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • Page 2 Step 9. Insert your 120VAC power supply wires through the strain relief and use the provided wire nuts to connect the white (common), black (hot), and green (ground) wires from the TW208P ThruWall fan to the appropriate common, hot and ground wires of your incoming power wires.
  • Page 3 Suncourt product. ONE YEAR WARRANTY Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the ThruWall Fan will, for 1 (one) year from date of original retail purchase, but not exceeding two years from date of manufacture, remain free from appearance of defects in workmanship or materials.

This manual is also suitable for:

Thruwall fan tw208p