Grundfos DMH 251 Installation And Operating Instructions Manual page 9

Dosing pump
Table of Contents

Advertisement

Pump type
Single pump
Double pump
DMH 213-10
DMH 213-10/213-10
DMH 291-10
DMH 291-10/291-10
DMH 46-16
DMH 46-16/46-16
DMH 97-16
DMH 97-16/97-16
DMH 136-16
DMH 136-16/136-16
DMH 166-16
DMH 166-16/166-16
DMH 202-16
DMH 202-16/202-16
DMH 276-16
DMH 276-16/276-16
DMH 255
DMH 194-10
DMH 194-10/194-10
DMH 270-10
DMH 270-10/270-10
DMH 332-10
DMH 332-10/332-10
DMH 403-10
DMH 403-10/403-10
DMH 550-10
DMH 550-10/550-10
DMH 257
DMH 220-10
DMH 220-10/220-10
DMH 440-10
DMH 440-10/440-10
DMH 575-10
DMH 575-10/575-10
DMH 750-4
DMH 750-4/750-4
DMH 770-10
DMH 770-10/770-10
DMH 880-10
DMH 880-10/880-10
DMH 1150-10
DMH 1150-10/1150-10
DMH 1500-4
DMH 1500-4/1500-4
* l/h per dosing head; double the capacity for double pumps.
The pump can be operated in the range between
Note
10 % and 100 % of the maximum dosing capacity.
6.4.1 Accuracy
Dosing flow fluctuation: smaller than ± 1 %
Linearity deviation: ± 1 % of the full-scale value (for water with
a fully deaerated dosing head).
6.4.2 Inlet pressure and counter-pressure / suction lift
Maximum inlet pressure
Pump type
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257
Minimum counter-pressure at the discharge valve of the
pump
Pump type
DMH 251
DMH 252
DMH 253
DMH 254
DMH 255
DMH 257
50 Hz
Max.
Q*
p max.
stroke
rate
[l/h]
[bar]
[n/min]
213
10
112
291
10
153
46
16
26
97
16
54
136
16
75
166
16
92
202
16
112
276
16
153
194
10
54
270
10
75
332
10
92
403
10
112
550
10
153
220
10
28
440
10
56
575
10
73
750
4
73
770
10
98
880
10
112
1150
10
146
1500
4
146
[bar]
8
8
5
5
0.8
0.8
[bar]
2
2
2
2
2
2
60 Hz
Max.
Q*
p max.
stroke
rate
[l/h]
[bar]
[n/min]
255
10
134
55
16
31
116
16
65
163
16
90
200
16
110
242
16
134
233
10
65
324
10
90
398
10
110
484
10
134
264
10
34
528
10
67
690
10
88
900
4
88
924
10
118
1056
10
134
A positive pressure difference of at least 2 bar is
required between the suction valve and the
discharge valve in order for the dosing pump to
operate correctly.
Note
If the total counter-pressure (at the dosing point)
and geodetic height difference between the
suction valve and the dosing point is less than
2 bar (20 m WC), a pressure-loading valve must
be installed immediately before the dosing point.
100 Hz
Max.
Q*
p max.
stroke
rate
[l/h]
[bar]
[n/min]
92
16
52
193
16
108
271
16
150
387
10
108
540
10
150
440
10
56
880
10
112
1150
10
146
1500
4
146
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dmh 252Dmh 253Dmh 254Dmh 255Dmh 256Dmh 257

Table of Contents