Grundfos DMH 251 Installation And Operating Instructions Manual page 15

Dosing pump
Table of Contents

Advertisement

3b
3a
2
DMH 257
Fig. 6
Pos.
Components
1p
Motor
2p
Worm gearing
3p
Eccentric
4p
Recuperating spring (not with drive size 3)
5p
Sliding plug
6p
Piston
7p
Crank
M
Combined overpressure and degassing valve
E
Degassing valve
9p
Diaphragm protection system (AMS)
Q
Dosing diaphragm
2
Dosing head
3a
Suction valve
3b
Discharge valve
L
Stroke-length adjustment knob
F
Oil-filling screw with dipstick
8.1.1 Combined overpressure and degassing valve
The combined overpressure and degassing valve (M) opens if
there is an excessive pressure build-up in the dosing system and
provokes the constant degassing of the hydraulic medium.
8.1.2 Diaphragm protection system AMS
The diaphragm protection system AMS (9p) has a keypad, which
is connected to the dosing diaphragm. The dosing diaphragm
oscillates freely in the dosing head and cannot be overstretched
due to a fault in the dosing system since the diaphragm protection
valve closes if such a fault occurs.
M
Q
9p
6p
5p
2p
3p
7p
8.1.3 Double-diaphragm system / diaphragm leakage
detection (optional)
General
The piston diaphragm and high-tech dosing pumps with drift-free
diaphragm leakage detection are equipped with the following:
dosing head with PTFE double-diaphragm system
ball non-return valve with built-in contact pressure gauge.
Double-diaphragm system
Dosing pumps with a double-diaphragm system with no
diaphragm leakage detection have no pressure gauge. In this
case the ball non-return valve is fitted with a locking unit. The
valve, however, can be retrofitted with a contact pressure gauge.
Ball non-return valve
In order for the diaphragm leakage detection to work and to
protect the diaphragms, the gap must be fully deaerated. Dosing
heads with a double diaphragm are equipped with a ball non-
return valve (T) to prevent air from flowing back during the filling
and deaeration process (2u).
Contact pressure gauge
Fig. 7
Pos.
Components
S
Contact pressure gauge
T
Ball non-return valve
U
Connection piece
2) For dosing heads with a double diaphragm with no contact
pressure gauge (no diaphragm leakage detection), a locking
unit is fitted instead of the contact pressure gauge.
1p
F
L
6s
S
5s
3u
4u
2)
2u
U
5u
3u
T
15