Download Print this page

Robitronic Overloader 2 Instruction Manual page 11

Advertisement

Profiles
Number of profile
- values between 0 and 9 are available.
- This number is linked with the profiles and is used to choose profiles in the
charge and discharge menu.
Profile name
- Profilenames are used, to identify profiles more quickly.
- To change the profilename press
DOWN
- Use
and
to set the positioncursor on the character you want to change.
UP
The charactercursor hightlights the selected character in the pool immediately.
_
+
-
and
changes the selected character in the pool and in the string simultaneously.
- To leave name setup menu press
Battery type
- 4 respectively 6 battery types are supported:
nickel-cadmium (NiMH/Cd)
nickel-metal-hydride (NiMH/Cd)
lithium-polymer (LiPO)
lithium-ion (Lixx)
lead-acid (PB)
gel-cell (PB)
- So the values NiMH/Cd, LiPO, Lixx, PB are available.
- Other profile settings depend on the selection of the battery type.
- Note, that battery type Lixx needs an additional setting of the charge end voltage
in the user setup menu.
- Use only battery types suitable to your batteries.
. The name setup menu appears.
ENTER /
START
profilename
positioncursor
charactercursor
character pool
MODE /
ENTER /
CANCEL
or
.
START