Set Black Mark Sensor As Media Sensor And Calibrate The Black Mark Sensor; Set Gap Sensor As Media Sensor And Calibrate The Gap Sensor - Polaroid P420T User Manual

Table of Contents

Advertisement

Printer configuration will be restored to defaults as below after initialization.
Parameter
Speed
Density
Label Width
Label Height
Sensor Type
Gap Setting
Print Direction
Reference Point
Offset
Tear Mode
Peel off Mode
Cutter Mode
Serial Port Settings
Code Page
Country Code
Clear Flash Memory
IP Address

4.3.4 Set Black Mark Sensor as Media Sensor and Calibrate the Black Mark Sensor

Please follow the steps as below.
1. Switch off the printer
2. Press the button while you switch on the printer
3. Release the button when LED turns green/amber after 5 green blinks. (Any green/amber will
do during the 5 blinks).
The LED color will change according to the following order:
Amber  red (5 blinks)  amber (5 blinks)  green (5 blinks)  green/amber (5 blinks)
 red/amber (5 blinks)  solid green

4.3.5 Set Gap Sensor as Media Sensor and Calibrate the Gap Sensor

Please follow the steps as below.
1. Switch off the printer
2. Press the button while you switch on the printer
Default setting
101.6 mm/sec (4 ips) (203DPI)
76 mm/sec (3 ips) (300DPI)
8
4" (101.5 mm)
4" (101.5 mm)
Gap sensor
0.12" (3.0 mm)
0
0,0 (upper left corner)
0
On
Off
Off
9600 bps, none parity, 8 data bits, 1 stop bit
850
001
No
DHCP
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents