To help protect your equipment from power surges and momentary power interruptions, we
strongly suggest that you use a battery-backed power supply (UPS) with this equipment.
DO NOT connect the AC power cord until all other connections have been completed.
DO NOT move the HC8 when powered up! This unit contains a hard drive which could be damaged by shock or
impact. Allow the hard drive to completely spin down before moving the HC8.
Unpack the HC8. Verify that you have all package contents. You should have received:
1
HC8
DB9 Male to RJ45 Adapter (8)
AC Power cord
Safety Sheet
HCREM Remote
Quick Install Guide (This Document)
AAA Batteries (2)
Rack Brackets (2)
The complete HC8 Installation manual and the current Core Module software can be found and
downloaded by going to www.elanhomesystems.com and following the dealer link. Be sure to
update the HC8 to the current Core Module software prior to programming.
Precision panel documentation is also located on the dealer site.
2
Mount the HC8 in the desired location. Use the included rack ears and screws if mounting in an equipment rack.
When choosing the location for the HC8 keep heat management and ventilation in mind. The HC8 should not be
directly located above heat sources such as amplifiers. When possible the HC8 should be mounted at the bottom of the
gear rack. In very warm locations (i.e.: enclosed rack or cabinet) leave a rack space above and/or below the HC8. For
can mount applications, use the can mounting bracket.
Serial Connections
3
Connect up to 8 RS232 controlled devices using the included DB9 to RJ45
adapters. Two RS485 ports are also available for a total of 10 serial ports.
Connect serial inputs from PPIS panels when using GCIREs. Suggested
Cat5 wiring is 568 for the RS232 port connections to the DB9-RJ45
adapters. Refer to the Integration Notes for Cat5 wiring for devices
connected to the RS485 ports.
VIA!Net Connections
4
Connect to PPVN precision panels to provide VIA!Net communication for
TS2 user interfaces. Connect to VIA!Net controlled devices like the M86A.
Use the ELAN standard color code for this connection.
Relay Connections
5
Connect to the PPCM precision panel to activate relay controlled devices like lifts, drapes and
movie screens located in the zones. Connect bare leads using the screw down terminals. Only
Room connections 1-2 on the PPCM have relay connections. Accepts up to 24V AC or DC and
current of up to 1 amp. Relay controlled devices may be directly connected if desired.
HC8
Can Mount Brackets (2)
Mounting Screws (8)
ELAN Standard
Insert wires in this order:
Blue
White/Blue
Orange
PR1
PR2
PR3
PR4
BL
OR
GR
BR
White/Orange
Green
White/Green
1 2 3 4 5
6
7
8
Brown
White/Brown
Quick Install Guide
Sense Input Connections
6
Connect to the Sense Input connections of the PPCM using 3.5mm stereo cables. This allows
ELAN sensors connected to PPRMs to be used to trigger events or to be used when conditionals
are required in programming. The connection from the HC8 provides power for the sensor.
Optionally, sensors may be connected directly to the HC8 sense inputs.
IR Output Connections
7
Connect to IR controlled devices at the head end or by using the PPCM to connect to
IR controlled devices located in zones. Use 3.5mm mono cables to connect to the
PPCM.
EXTERNAL IR Input Connection
8
Connect to the EXT IR IN connection of a PPVN or the PPCM. This connection allows the HC8 to
receive IR input from a TS2's IR receiver (through the PPVN) or from an IR sensor connected to a
PPRM, PPIS or PPIR (through the PPCM). If you need to connect both the PPCM and a PPVN to
the EXT IR In of the HC8 an IR connecting block can be used. An IR sensor can be directly
connected if desired.
Audio Output Connection
9
Connect to the source inputs of the A/V Controller. These are the line level audio output of
the Internal Player. Requires a 3.5mm stereo mini to RCA adapter.
10
Video In/Out Connections
Connect the Video Output to the component input of a monitor to provide the On Screen
Display of the HC8. Connect the Video Inputs to the component video output of the A/V
Controller to allow video to loop through the HC8 when the OSD is not being displayed.
Ethernet and USB Connections
11
Connect the Ethernet connector to a switch or router to allow the HC8 to communicate on
the network.
Connect the USB connection to the dial-up modem for Voice Mail applications.
12
Connect AC Power Cord
Verify the HC8 is powered using the Activity Indicator LEDs.
Verify the HC8 is on the network
13
Using the g! Configuration software verify the HC8 is on the network. You can also "ping" the
HC8's IP address from a computer that is on the network.
The HC8 comes from the factory as a DHCP client. We recommend changing the IP address
using the "Config IP Info" button on g! ConnectPro to a dedicated static address outside of the
DHCP range of your network.
P/N 9901085
Rev. C - 3/10/11

Advertisement

loading

Summary of Contents for Elan HC8

  • Page 1 Optionally, sensors may be connected directly to the HC8 sense inputs. DO NOT move the HC8 when powered up! This unit contains a hard drive which could be damaged by shock or impact. Allow the hard drive to completely spin down before moving the HC8.
  • Page 2 Connect to the PPCM and LEDS Connect to Sense Input AC Power Connection A/V Controller to a VIA!Net devices like the connections on the monitor. M86A. Uses the ELAN PPCM. standard color code. Serial Connections Relay Connections IR Outputs Audio Outputs Ethernet Connection 8 RS232 and 2 RS485 ports.