ATX Power/ 电源
No.
Pin Define
No.
Pin Define
5
1
3.3V
13
3.3V
1
2
3.3V
14
-12V
13
3
GND
15
GND
4
+5V
16
PS_ON
5
GND
17
GND
1
6
+5V
18
GND
7
GND
19
GND
8
Power Good
20
-5V
9
5VSB
21
+5V
24
10
+12V
22
+5V
12
11
+12V
23
+5V
12
3.3V
24
GND
1
No.
Pin Define
No.
Pin Define
5
1
1
GND
5
+12V
2
GND
6
+12V
3
3
GND
7
+12V
8
4
4
GND
8
+12V
Front Panel Header/ 前面板
No.
Pin Define
No.
Pin Define
1
2
1
Power LED+
2
5V Standby
3
No Pin
4
ID LED+
6
ID LED-
5
Power LED-
7
HDD LED+
8
System Status LED (Green)
9
HDD LED-
10
System Status LED (Amber)
11
Power Button
12
LAN1 Active LED+
14
LAN1 Link LED-
13
GND
15
Reset Button+
16
SMBus Data
17
GND
18
SMBus Clock
23
24
19
ID Switch+
20
Case Open
21
ID Switch-
22
LAN2 Active LED
23
NMI Switch-
24
LAN2 Link LED-
SATA Connector/SATA
TPM Connector/
接口
No.
Pin Define
No.
7
1
GND
1
2
TXP
2
1 2
3
TXN
3
4
GND
4
5
RXN
5
1
6
RXP
6
7
GND
7
8
13 14
9
10
11
12
13
14
BMC Firmware Readiness LED
SATA/sSATA SGPIO Header/ 串行 GPIO
No.
Pin Define
BMC Firmware Readiness LED (LED_BMC):
1
Data In
State
Description
2
No Pin
On
BMC firmware is initial
2
8
3
Data Out
Blink
BMC firmware is ready
4
GND
Off
AC loss
5
GND
1
7
6
Load
7
No Connect
8
Clock
Intel Raid Header
Intel RAID Key Header (SW_RAID):
2
No.
1
2
1
MD80-TM1 Quick Reference Guide/ 快速测试参考指南
7
1 2 3
4
5
6
10
11
12
13
14
15
16
17
18
19
26
20
21
22
23
24
27
25
PMBUS
CPU/System FAN/
No.
Pin Define
1
PMBus Clock
4
2
PMBus Data
3
PMBus Alert
4
1
4
GND
5
3.3V Sense
1
IPMB
No.
Pin Define
1
GND
2
+12V
No.
Pin Define
3
Sensor
4
Speed Control
1
Clock
2
GND
3
Data
HDD Back Plane Board Header/
硬盤背板排針
No.
Pin Define
No.
Pin Define
1 2
1
BP_SGP_CLK
2
No Connect
4
FAN_SGP_GLD
3
BP_SGP_GLD
5
BP_SGP_DOUT
6
GND
8
Reset
7
Key Pin
10
BP_LED_A_N
9
GND
12
GND
11
BP_LED_G_N
14
No Connect
13
BP_SGP_DIN
16
SMB_BP_DATA
15
GND
18
SMB_BP_CLK
17
GND
20
BMC_ACK
19
P_3V3_AUX
25 26
22
BMC_REQ
21
P_3V3_AUX
24
Key Pin
23
GND
26
GND
25
BP_PRESENSE
USB 3.0 Header
可信平台模块
Pin Define
No.
Pin Define
CLK_33M_TPM_CONN
1
Power
P_3V3_AUX
2
IntA_P1_SSRX-
20
1
LPC_RST
3
IntA_P1_SSRX+
P3V3
4
GND
LPC_LAD0
5
IntA_P1_SSTX-
IRQ_SERIAL
6
IntA_P1_SSTX+
LPC_LAD1
7
GND
No Connect
11
10
8
IntA_P1_D-
LPC_LAD2
9
IntA_P1_D+
NC
10
No Connect
LPC_LAD3
11
IntA_P2_D+
GND
12
IntA_P2_D-
LPC_FRAME_N
13
GND
GND
14
IntA_P2_SSTX+
15
IntA_P2_SSTX-
16
GND
17
IntA_P2_SSRX+
18
IntA_P2_SSRX-
19
Power
20
No Pin
Case Open Intrusion Header
Open: Normal operation.
Pin Define
Key Pin
GND
Closed: Active chassis intrustion alert.
No.
Code
Description
1
CPU1_FAN
CPU1 fan connector (for Secondary CPU)
2
SW_ID
ID switch button
8
3
USB3_MLAN
BMC Management LAN port (top) / USB 3.0 ports (bottom)
4
LAN1
LAN port #1
5
LAN2
LAN port #2
6
VGA
VGA port
7
COM1
Serial port
8
P12V_AUX2
8 pin power connector (for secondary CPU)
9
PMBUS
PMBus connector
10
DIMM_P1_G0
Channel 3 slot 0 (for secondary CPU)
11
DIMM_P1_G1
Channel 3 slot 1 (for secondary CPU)
12
DIMM_P1_G2
Channel 3 slot 2 (for secondary CPU)
13
DIMM_P1_H0
Channel 4 slot 0 (for secondary CPU)
14
DIMM_P1_H1
Channel 4 slot 1 (for secondary CPU)
15
DIMM_P1_H2
Channel 4 slot 2 (for secondary CPU)
16
CPU1
Intel LGA2011 Socket R (Secondary CPU)
17
ATX1
24 pin main power connector
9
18
DIMM_P0_A0
Channel 1 slot 0 (for primary CPU)
19
DIMM_P0_A1
Channel 1 slot 1 (for primary CPU)
20
DIMM_P0_A2
Channel 1 slot 2 (for primary CPU)
21
DIMM_P0_B0
Channel 2 slot 0 (for primary CPU)
22
DIMM_P0_B1
Channel 2 slot 1 (for primary CPU)
23
DIMM_P0_B2
Channel 2 slot 2 (for primary CPU)
24
P12V_AUX1
8 pin power connector (for primary CPU)
25
SYS_FAN5
System fan connector#5
26
CPU0
Intel LGA2011 Socket R (Primary CPU)
27
CPU0_FAN
CPU0 fan connector (for Primary CPU)
28
DIMM_P0_D2
Channel 4 slot 2 (for primary CPU)
29
DIMM_P0_D1
Channel 4 slot 1 (for primary CPU)
30
DIMM_P0_D0
Channel 4 slot 0 (for primary CPU)
31
DIMM_P0_C2
Channel 3 slot 2 (for primary CPU)
32
DIMM_P0_C1
Channel 3 slot 1 (for primary CPU)
33
DIMM_P0_C0
Channel 3 slot 0 (for primary CPU)
34
SYS_FAN4
System fan connector#4
35
SYS_FAN3
System fan connector#3
1
2
3
风扇
No.
Desription
1
Serial port
2
Video port
3
GbE Eternet LAN ports
4
KVM Server Management 10/100/1000 LAN Port (Dedicated LAN Port)
5
USB 3.0 ports
6
Power button/LED
Installing CPU/ 安装处理器
2
3
1
4 5
6
7
No.
Code
Description
36
SYS_FAN2
System fan connector#2
37
SYS_FAN1
System fan connector#1
38
SSATA_SGP
sSATA SGPIO header
39
SATA_SGP
SATA SGPIO header
40
SATA0/1/2/3/4/5 SATA 3 6Gb/s connectors
41
SW_RAID
Intel Software RAID Key jumper
42
CASE_OPEN
Case open intrusion alert header
43
ME_UPDATE
ME update jumper
44
ME_RCVR
ME recovry jumper
45
BIOS_PWD
Clearing Supervisor Password jumper
46
BIOS_RCVR
BIOS recovery jumper
47
SSATA0/1/2/3
SATA 3 6Gb/s connectors
48
F_USB3
USB 3.0 header
49
FP_1
Front panel header
50
IPMB
IPMB connector
51
BP_1
HDD back plane board header
52
TPM
TPM module connector
53
PCIE_1
PCI Express x8 slot
54
PCIE_2
PCI Express x8 slot
55
PCIE_3
PCI Express x8 slot
56
PCIE_4
PCI Express x16 slot
57
LED_BMC
BMC firmware readiness LED
58
BMC_FRB
Force to Stop FRB Timer jumper
59
S3_MASK
S3 Power On Select jumper
60
BUZZER1
Buzzer
61
CLR_CMOS
Clear CMOS jumper
62
M2_SK
M.2 slot
63
BAT
Battery socket
64
DIMM_P1_E0
Channel 4 slot 0 (for secondary CPU)
65
DIMM_P1_E1
Channel 4 slot 1 (for secondary CPU)
66
DIMM_P1_E2
Channel 4 slot 2 (for secondary CPU)
67
DIMM_P1_F0
Channel 3 slot 0 (for secondary CPU)
68
DIMM_P1_F1
Channel 3 slot 1 (for secondary CPU)
69
DIMM_P1_F2
Channel 3 slot 2 (for secondary CPU)
Rear I/O Connector/ 后面板接口
4
4
10/100/1000 LAN LED:
State
3
Yellow On
6
Green On
Speed LED
Link/Activity
5
LED
Off
Memory Population Configuration/ 安装内存
Type
RDIMM
RDIMM
RDIMM
RDIMM
LRDIMM
 When only one DIMM is used, it must be populated in memory slot0 first.
 Memory populated sequence must be followed with slot0/slot1/slot2
 System will not boot normally with incorrect populated sequence.
 只使用一个DIMM时,必须安装到内存插槽0。
 内存安装顺序必须是 插槽0/插槽1/插槽2。
 若安装顺序有误,系统将无法正常
Jumper Settings/ 跳线设置
No.
Desription
1
Clear CMOS Jumper
1-2 Close: Normal operation (Default setting)
2-3 Close: Clear CMOS data.
2
Force to Stop FRB Timer Jumper
1-2 Close: Normal operation. (Default setting)
2-3 Close: Force to Stop FRB Timer.
3
S3 Power On Select Jumper
1-2 Close: Stop an initial power on when BMC is not ready.
2-3 Close: Keep initial power on. (Default setting)
4
BIOS Recovery Jumper
1-2 Close: Normal operation. (Default setting)
2-3 Close: BIOS recovery mode.
5
Clearing Supervisor Password Jumper
1-2 Close: Normal operation. (Default setting)
2-3 Close: Skip supervisor password.
6
Power button/LED:
Description
State
Description
1Gbps data arte
Green On
System is powered on
Off
System is powered off
100Mbps data arte
10Mbps data arte
Speed (MT/s);
Slot Per Channel (SPC) and DIMM Per Channel (DPC)
Ranks Per
DIMM and
2 Slot Per Channel
Data Width
1 Slot Per Channel
1DPC
1DPC
2DPC
SRx4
2133
2133
1866
SRx8
2133
2133
1866
DRx8
2133
2133
1866
DRx4
2133
2133
1866
QRx4
2133
2133
2133
开机。
No.
Desription
6
ME Recovery Jumper
1-2 Close: Normal operation. (Default setting)
2-3 Close: ME recovery mode.
7
ME Update Jumper
1-2 Close: Normal operation (Default setting)
2-3 Close: ME update.
P/N:12QM1-MD80T0-00R

Advertisement

loading
Need help?

Need help?

Do you have a question about the MD80-TM1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Gigabyte MD80-TM1

  • Page 1 MD80-TM1 Quick Reference Guide/ 快速测试参考指南 1 2 3 Code Description Code Description CPU1_FAN CPU1 fan connector (for Secondary CPU) SYS_FAN2 System fan connector#2 SW_ID ID switch button SYS_FAN1 System fan connector#1 USB3_MLAN BMC Management LAN port (top) / USB 3.0 ports (bottom)
  • Page 2 Restriction of Hazardous Substances (RoHS) Directive Statement GIGABYTE products have not intended to add and safe from hazardous substances (Cd, Pb, Hg, Cr+6, PBDE and PBB). The parts and components have been carefully selected to meet RoHS requirement. Moreover, we at GIGABYTE are continuing our efforts to develop products that do not use internationally banned toxic chemicals.