Locations 000-003: Programming The Master Arm/Disarm Code
Locations 000-003 contain master arm/disarm code (user number 1). Location 000 contains the first digit of the code;
location 003 contains the fourth digit of the code. THE CODE MUST CONTAIN FOUR (4) DIGITS. The master code
can then be used in the RUN mode to enter arm/disarm codes 1-30. The factory default code is [1][2][3][4].
Locations 004-055: Programming The Arm/Disarm Code For Users 2 Thru 14
Locations 004-055 contain the arm/disarm codes for users 2 thru 14. Location 004 contains the first digit of the code
#2, and location 007 contains the fourth digit of code #2. THESE CODES MUST CONTAIN FOUR (4) DIGITS. To
disable a code, PROGRAM a "15" as the first digit of the code. These codes can be changed in the RUN mode using
the master code. Factory default is "15", disabled.
Locations 056-059: Programming The Arm/Disarm Code For User 15 (Duress Code)
Locations 055-059 contain the arm/disarm code for user number 15 (Duress Code). Duress capability is enabled
by programming a communicator code in location 320-323. If locations 320-323 are left unprogrammed, user
number 15 will act as a standard user code. Factory default is "15", disabled.
Locations 060-063: Programming The "Go To Program" Access Code
Locations 060-063 contain the "Go To Program" access code. Location 060 Contains the first digit of the code and
location 063 contains the fourth digit of the code. THE CODE MUST CONTAIN FOUR (4) DIGITS. With the Ranger
9000E disarmed, the "Go To Program" access code can be used to enter the program mode. To disable the "Go To
Program" access code, program a "15" in location 060. The factory default setting is [9][7][1][3]. NOTE: The first digit
of this code should not match the Quick-Arm digit.
Locations 064-079: Users 1-15 Arm/Disarm Code Enable By Partition
PARTITIONED SYSTEMS
If partitions are utilized, codes may be assigned to a
specific partition by using locations 064-079. This is
done by enabling each individual code (code 1 is
location 064, code 15 is location 079) for each of the
four partitions that code should have access to.
Codes are selected by adding the value for each
partition together and placing that number in the
proper location.
NON - PARTITIONED SYSTEMS
When partitioning is not being utilized, locations
064-079 can be used to control the arming and
disarming authority of the individual arm/disarm
codes. A code can be given limited authority by
programming a number from 1 to 15 in the
corresponding location for that code. Add the values
in the table that correspond to the desired
arm/disarm characteristics, and program the sum in
the appropriate locations.
VALUE
1
2
4
8
VALUE
1
2
4
8
8
PARTITIONS
PARTITION 1
PARTITION 2
PARTITION 3
PARTITION 4
CHARACTERISTIC
STANDARD ARM/DISARM CODE
ARM ONLY AFTER CLOSING TIME
ARM ONLY CODE
OPEN/CLOSE REPORTS FOR USER