Ranger 9000E Installation Manual page 26

Downloadable control communicator
Table of Contents

Advertisement

Location 331: Phone #1, 2, Internal Log, Listen-In, Or Any Combination For Reporting Keypad Auxiliary 2
(Double Keypress [4] & [6])
Locations 332-334: Communicator Code For Keypad Panic (Double Keypress [
The Ranger 9000E will report a Keypad Panic code and activate the Burglary siren each time the [ r ] and [#] keys
are pressed simultaneously on the keypad. The desired 1 to 3 digit Keypad Panic code is programmed in these
locations. If all locations are "0", the Keypad Panic double keypress is disabled. If activated, the siren can be
silenced by entering any Arm/Disarm code.
Location 335: Phone #1, 2, Internal Log, Listen-In, Or Any Combination For Reporting Keypad Panic (Double
r r
Keypress [
] & [#]) See Location 259)
Locations 336-338: Communicator Code For Keypad Tamper Feature
The optional Keypad Tamper feature that, when enabled, will lock out the keypads for 1 minute if 30 random
keypresses are made without producing a valid code. The desired 1 to 3 digit Keypad Tamper code must be
programmed in these locations to enable this feature. If all locations are "0", the Keypad Tamper feature will not
be enabled or reported.
Location 339: Phone #1, 2, Internal Log, Listen-In, Or Any Combination For Reporting Keypad Tamper
(See Location 259)
Locations 340-342: Communicator Code For Autotest Reports
The Ranger 9000E has the ability to send Autotest reports at intervals from 1 to 99 days. The desired 1 to 3 digit
code must be entered in these location(s) to enable the Autotest feature. If all locations are "0", Autotest is
disabled. (NOTE: WHEN USING AUTOTEST, LOCATIONS 616-621 and 624-635 MUST BE PROGRAMMED.)
Location 343: Phone #1, 2, Internal Log, Listen-In, Or Any Combination For Autotest Reports (See Loc. 259)
Location 344: Phone Selector For Bypass Reports (See Location 259)
If this location is "0", bypass reports will follow the individual zone phone selections. If this location contains
something other than "0", it will be used for all bypass reports. If bypass reports are to go to the log without reporting,
program a "4" in this location.
Location 345: Phone Selector For Trouble Reports (See Location 259)
If this location is "0", trouble reports will follow the individual zone phone selections. If this location contains
something other than "0", it will be used for all trouble reports. If trouble reports are to go to the log without reporting,
program a "4" in this location.
Location 346: Partition Open/Close Report Selector
The number programmed in this location will select
the partition(s) that will send open/close reports.
Refer to the table below, and add the values of the
partitions for open/close reports, and program the
appropriate data in this location. Factory default is
"0", enabling open/close reports for all partitions.
Example: For open/close reports from partitions
#1 and #3, program a "5" (1 + 4 = "5") in this
location.
(See Location 259)
VALUE
1
2
4
8
26
r r
] & [#])
PARTITION NUMBER(S)
PARTITION #1
PARTITION #2
PARTITION #3
PARTITION #4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents