Communicator Format Selections - Ranger 9000E Installation Manual

Downloadable control communicator
Table of Contents

Advertisement

DATA
"0"
LOCAL ONLY
"1"
ADEMCO CONTACT ID
"2"
ADEMCO 4/2 EXPRESS
"3"
FBI SUPERFAST
"4"
PAGER
"5"
RADIONICS EXTENDED SLOW
"6"
CADDX MODEM
"7"
RADIONICS EXTENDED FAST
"8"
RADIONICS EXTENDED FAST
"9"
RADIONICS EXTENDED FAST
WITH PARITY
"10"
UNIVERSAL 4 + 2
"11"
ADEMCO/SILENT KNIGHT SLOW
"12"
SILENT KNIGHT 4+2 FAST
"13"
SESCOA/FRANKLIN FAST
"14"
SIA
"15"
OVER-RIDE ENABLE
Locations 124-127: Account Code Three For Partition #3
Locations 124-127 are utilized to assign an account code for partition #3 if a unique code is desired. If these
locations contain "0", the account code listed in locations 96-100 will be used. If a 3 digit code is used, program a
"0" in location 127. If location 132 contains a "4", this account code is disabled.
Locations 128-131: Account Code Four For Partition #4
Locations 128-131 are utilized to assign an account code for partition #4 if a unique code is desired. If these
locations contain a "0", the account code listed in locations 96-100 will be used. If a 3 digit code is used, program
a "0" in location 131. If location 132 contains a "4", this account code is disabled.
FORMAT
DESCRIPTION
COMMUNICATOR IS DISABLED
DTMF FORMAT
(SEE APPENDIX 2)
DTMF FORMAT
DTMF FORMAT 2300Hz
DTMF FORMAT
1800Hz TRANSMITTAL 2300Hz HANDSHAKE 20 PPS
HEX EXTENDED DOUBLE ROUND
PROPRIETARY
1800Hz TRANSMITTAL 2300Hz HANDSHAKE 40 PPS
HEX EXTENDED DOUBLE ROUND
1800Hz TRANSMITTAL 1400Hz HANDSHAKE 40 PPS
HEX EXTENDED DOUBLE ROUND
1800Hz TRANSMITTAL 2300Hz HANDSHAKE 40 PPS
HEX EXTENDED
1800Hz TRANSMITTAL 2300Hz HANDSHAKE
DOUBLE ROUND 20PPS
1900Hz TRANSMITTAL 1400Hz HANDSHAKE 10 PPS
DOUBLE ROUND PARITY
1900Hz TRANSMITTAL 1400Hz HANDSHAKE 20 PPS
DOUBLE ROUND PARITY ADD HEX
1800Hz TRANSMITTAL 2300Hz HANDSHAKE 20 PPS
HEX DOUBLE ROUND
FSK FORMAT
(SEE APPENDIX 1)
SEE LOCATIONS 610-615
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents