Programming The Auxiliary Outputs - Ranger 9000E Installation Manual

Downloadable control communicator
Table of Contents

Advertisement

Location 220: Automatic Bypass / Instant Arming
Location 220 is used to enable options, or a combination of options as described in the table below. Choose the
option desired, and program the corresponding data in location 220.
DATA
"0"
Automatic Bypass / Instant Arming Disabled.
"1"
Automatically enter the Instant mode and bypass interior follower zones if an Entry/Exit zone is
not faulted during exit delay time.
"3"
Interior follower zones will auto bypass if Entry/Exit zones are not faulted during exit delay time.
Pressing [ r ] will toggle Instant mode on Entry/Exit zone. This is factory default.
"4"
"5"
Automatically enter the Instant mode and bypass interior follower zones if an Entry/Exit zone is
not faulted during exit delay time. Pressing [ r ] will toggle Instant mode.
"7"
Automatically bypass interior follower zones if an Entry/Exit zone is not faulted during exit delay
time. Pressing [ r ] will toggle Instant mode.
NOTE: When the "Instant" light is on, Entry/Exit zones are instant; when off, Entry/Exit zones are delayed. Factory
default is "4" and the Instant feature will toggle by pressing the [ r ] key. If Automatic Bypass is enabled, it will
override the Entry-Guard feature.
Location 221: Delay Of Phone Line Seizure For Abort
Location 221 contains the number of 2 second increments the phone line seizure and communicator output will be
delayed prior to an attempt to communicate. If a "1" is programmed in this location, the delay will be 2 seconds.
If a "15" is programmed in this location, the delay will be 30 seconds. Factory default is "0", and there is no delay
before the initiation of an event report. NOTE: Only non-24 hour zones will delay.
Location 222: Programming The Quick Arm Digit
The Ranger 9000E can be programmed to Quick Arm with one digit by programming a digit (1-9) in location 222.
This number cannot be the first digit of the programming code or of the Chime enable code. Factory default is "0"
which disables this feature. The Quick-Arm digit will send a closing by user 29 if closings are enabled in Location
350.
Location 223: Entry-Guard Entry Delay Time
Location 223 contains the number of 10 second increments in the Entry-Guard entry delay time. The delay time
can be programmed in 10 second increments from 10 to 150 seconds. ("1" = 10 seconds through "15" = 150
seconds). For example, programming a "4" in this location will create a delay time of 40 seconds. Factory default
is "2" (20 seconds).
Locations 224-239: Programming the Auxiliary Output Options
Locations 224 through 239 control the output options for the four auxiliary outputs. Each of the four pins has four
individual programming locations that will be referred to in this section as DATA 1, DATA 2, DATA 3, and DATA 4.
There are 256 events or conditions that can be programmed to activate these four auxiliary outputs. The following
descriptions of these data locations will help you to understand how to program each of these locations.
DESCRIPTION