Conair HTC 30 User Manual page 134

Energysmart dryer w series models 600 through 5000 with touchview technology
Table of Contents

Advertisement

IMPORTANT: Always refer
to the wiring diagrams that
came with your GasTrac
before making electrical
connections.
IMPORTANT: Always refer
to the wiring diagrams that
came with your GasTrac
before making electrical
connections.
3 - 1 0 4
l I n s t a l l a t i o n - Te s t i n g
Te s t i n g t h e I n s t a l l a t i o n o f t h e
G a s Tr a c
( c o n t i n u e d )
7
Verify the combustion blower is rotating in the correct direction. The
combustion blower uses a three-phase blower. Hold a strip of paper or piece
of string near the blower inlet filter. If the paper or string blows away from
the filter, the blower is rotating in the wrong direction. Stop the GasTrac.
Disconnect and lockout the main power source. Reverse any two incoming
electrical leads on the blower at the VFD output and repeat the test procedure.
8
Allow the actual temperature to reach setpoint.
9
Once the setpoint is reached, press the "STOP" button.
• The green RUN indicator light turns off.
• The gas inlet valves should close.
• The combustion blower should stop.
• The burner and temperature controllers should display STANDBY.
10
After the test has been completed successfully, turn off the power to the
GasTrac, allow to cool, and properly shut down the dryer,
section entitled, Stopping the EnergySmart Dryer System.
Combustion
Blower Inlet
Filter
see Operation

Hide quick links: