Specifications
Function
Humidity
Temperature (Air)
Temperature (InfraRed)
(@25ºC ±5ºC)
Display
Sensor Type
Dew Point
Wet Bulb
IR Emissivity
IR Spot/Distance Ratio
IR Response Time
Operating Conditions
Storage Conditions
Power Supply
Battery Life
Dimensions / Weight
Meter Description
1.
Emissivity adjust indicator
2.
Laser pointer on indicator
3.
Low Battery indicator
4.
IR Surface Temperature button
5.
ON/OFF/Setup button
6.
Back Light button
7.
Laser/Down button
8.
°F/°C/Up button
9.
Dew Point/Wet Bulb button
10. % Humidity display
11. Air Temperature, Dew Point or Wet Bulb display
12. IR Surface Temperature display
13. Extended probe with Humidity &
Air Temperature Sensors
14. PC interface port
15. AC adaptor jack
Note: The battery compartment is located on the rear of the instrument
Range and Resolution
0.0 to 100.0% RH
o
-4.0 to 122.0
F (-20 to 50
o
-4 to 842
F (-20 to 450
o
-40 to -4
F, 842 to 932
o
-40 to -20
C, 450 to 500
Triple LCD with backlight
Humidity: Capacitance sensor; Temperature (air): Thermistor
o
-90.4 to 122.0
F (-68 to 50
temperature measurements)
o
-6.9 to 122.0
F (-21.6 to 50
temperature measurements)
Adjustable from 0.3 to 0.99
8:1
0.5 seconds
o
o
-4 to 122
F (-20 to 50
o
-40 to 185
F (-40 to 85
4 x 1.5V 'AAA' batteries or AC adaptor
approx. 150 hours (laser inactive); 30 hours (laser active)
6.8x2.7x1.9" (175x70x50mm); 4.9 oz. (140g)
2
Accuracy
±3% RH (10 to 90%)
o
o
o
C) ±1.8
F (±1
C)
±3% reading or ±3
o
C)
whichever is greater
o
F
±4% reading or ±4
o
whichever is greater
C
o
C) (calculated from humidity and
o
C) (calculated from humidity and
C); < 99% RH non-condensing
o
C); <99% RH non-condensing
1
DP
2
Wb
H
umi
3
4
5
6
o
o
C/6
F
o
o
C/8
F
13
C
12
11
%
10
15
9
14
8
7
RH401 V1.4 11/07
Need help?
Do you have a question about the RH401 and is the answer not in the manual?