Fujitsu PRIMERGY CX2550 M4 Operating Manual page 56

Server node
Hide thumbs Also See for PRIMERGY CX2550 M4:
Table of Contents

Advertisement

Starting up and operation
Pos.
Label
2
ID
3
[CSS]
4
Pos.
Label
1
56
Indicator
Status
ID indicator,
blue on
see also
"iRMC-
related
status
blue
signals" on
flashing
page 57
off
CSS
orange on
indicator
orange
flashing
off
orange on
Global Error
indicator,
see also
"iRMC-
related
status
orange
signals" on
flashing
page 57
Button
Function
Used to switch the server on or off.
I
On/Off button
Operating Manual
Description
The system has been selected by
pressing on the ID button in the
chassis front panel.
The server has been highlighted for
easy identification using the iRMC
(AVR) with disabled local VGA
output.
No critical event detected (CSS
component).
Prefailure event detected (CSS
component).
CSS component failure detected.
No critical event detected (non CSS
component).
Prefailure event detected (non CSS
component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
If the system is running an ACPI-
compliant operating system, pressing
the On/Off button will perform a graceful
shutdown.