Capacity Compensation Rate For Pipe Length And Height Difference; Models: Aoyg07Kgca, Aoyg09Kgca, Aoyg12Kgca, And Aoyg14Kgca - Fujitsu AOYG07KGCA Design & Technical Manual

Wall mounted type
Hide thumbs Also See for AOYG07KGCA:
Table of Contents

Advertisement

6. Capacity compensation rate for pipe length and height
difference
Indoor unit is higher than outdoor unit
Indoor unit
Connection pipe
6-1. Models: AOYG07KGCA, AOYG09KGCA, AOYG12KGCA,
and AOYG14KGCA
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
HEATING
Indoor unit is higher than
outdoor unit *1
Indoor unit is lower than
outdoor unit *2
Height difference H
1
*
H
Outdoor unit
5
15
10
7.5
5
0.992
0
1.000
-5
1.000
-7.5
-10
-15
5
15
10
7.5
5
1.000
0
1.000
-5
0.995
-7.5
-10
-15
- 51 -
Indoor unit is lower than outdoor unit
Outdoor unit
H
Indoor unit
Connection pipe
Pipe length (m)
7.5
10
0.929
0.960
0.933
0.964
0.937
0.972
0.944
0.972
0.944
0.972
0.944
0.944
Pipe length (m)
7.5
10
0.968
0.994
0.968
0.994
0.968
0.994
0.968
0.989
0.963
0.987
0.961
0.959
2
*
15
20
0.858
0.868
0.872
0.882
0.876
0.885
0.879
0.889
0.887
0.896
0.887
0.896
0.887
0.896
0.887
0.896
0.887
0.896
15
20
0.896
0.879
0.890
0.879
0.896
0.879
0.896
0.879
0.896
0.879
0.891
0.875
0.889
0.873
0.887
0.871
0.878
0.862