Safety Devices - Fujitsu AOYG07KGCA Design & Technical Manual

Wall mounted type
Hide thumbs Also See for AOYG07KGCA:
Table of Contents

Advertisement

11. Safety devices

Type of
protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Type of
protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Protection form
Activate
Reset
Activate
Reset
Protection form
Activate
Reset
Activate
Reset
- 59 -
Model
AOYG07KGCA
250 V, 20 A
250 V, 5 A
125±25 °C
Fan motor stop
100±25 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
Model
AOYG12KGCA
250 V, 20 A
250 V, 5 A
125±25 °C
Fan motor stop
100±25 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart