8. Secure the drain support bracket with the two
screws included in the accessory package.
See Figure 6.
Figure 6
9. Rotate the drain fitting so it is facing the gen-
eral direction of the drain support bracket.
10. Locate the drain pipe. Apply any remaining
Loctite 565 thread sealant to one end of the
1/2" drain pipe. Slide the drain pipe through
the drain support bracket so the end of the
drain pipe with thread sealant can be thread-
ed into the hexagonal drain fitting.
11. Turn the drain pipe clockwise so it threads
into the drain fitting. Tighten the drain pipe
while supporting the hexagonal drain fitting.
See Figure 7.
Figure 7
8
TRANSFLOW Transmission Cooling System Service Tool J-45096
12. To complete the waste vessel drain set up,
connect the fitting of your choice to the male
1/2" pipe that is now installed. See Figure 8.
Figure 8

Power Up

1. Connect the red battery clip to the positive
(+) battery post on the vehicle, and connect
the negative lead to a known good chassis
ground. See Figure 1.