Index Foreword ........................3 Safety Information ....................4 Before installing, uninstalling, or troubleshooting ..........5 Before the operation ................... 5 During the operation ................... 5 Repairs ........................6 Warranty ........................6 Maintenance / Cleaning ................... 6 Assembly ......................... 7 Reset ........................11 Operation .......................
The assembly of the table frame must be made in accordance with this manual. Changes to the table frame or improper use may affect the safety, function and life! This manual is for all OBLIQUE Adapt sit-stand tables with HDU provided. Due to different models or types pictures can be different.
Safety Information Safe use of the sit-stand table is only possible if the instructions are read and are strictly observed. Failure to observe instructions could result in significant damage or injuries. Anyone who has assembled this sit-stand desk or is a user of the desk must have access to these instructions.
Before installing, uninstalling, or troubleshooting Stop the sit-stand table. Turn the power off and unplug the power cord. Unload the sit-stand table of any weight. The opening and exchange of electrical equipment may only be performed by qualified electricians. The table must not to be used in wet areas, e.g. Pools. The table must not to be used in hazardous environments.
To avoid malfunction, all repairs done by authorized service personnel. WARNING! Should the user attempt to repair or open any part of the desk system then warranty is null and void. In such a case VERCO are not liable for any failures sustained.
Assembly In the assembly of the table frame, use only the bolts to the prescribed specifications. WARNING! Incorrect screws can cause damage to the table. For columns with fixed welded feet continue with step 2. For columns with bolted feet, they must assembled first on the columns (please use the bolts to the table frame-drawing).
Page 8
Now install the two beams and the desktop support on the two Columns. Use only the M8 screws, according to the frame-drawing! The max. tightening torque for these screws is 20 Nm The max. The 2x internal screw are The 2x external screw are to to screw in the threads of screw in the threads of the the beams...
Page 9
Fasten your desktop on the table frame. On the beams holes with an ø6.5 mm are provided for fixing the desk top (recommended screws ø5.5 to ø6.0 mm). Install the control unit and the handset on the desktop. On the control unit you have ø5.5 mm holes and at the handset you have ø4.5 mm holes.
Page 10
Sensor Connections to the control unit M1-M3 = Connectors for the drives = Connectors for the handset = Connector for the power cord (3-pin)
Reset The desk may need to be reprogrammed / reset after any of the following: After assembly; after disconnection from the power supply or after any impact on the table top. In the case of a reset becoming necessary downward movement of the table at a reduced speed is possible.
Adjustment of the altitude display If the indicated value does not match the actual height of the tabletop, the display can be corrected as follows: Press the S key and release the button again. Press the DOWN key until the display start to flash (about 5 sec.) Measure the table height and enter the measured value (depending on the setting in centimeters or inches) with the UP or DOWN button.
Page 13
To save a position: Drive the table with "Up" or "down" to the desired height. Then press the "S" key (in the display "S -" is displayed) and then a position of the 1-4 buttons (the display will show as "S1"). The save procedure is confirmed by the control unit with a double click sound and after about 2 seconds, the LCD shows the current table height.
Page 14
Adjustment of the height display If the indicated amount does not match the actual height of the tabletop, the display can be corrected as follows: Press the S key and release the button again. Press the DOWN key until the display start to flash (about 5 sec.). Measure the table height and enter the measured value (depending on the setting in centimeters or inches) with the UP or DOWN button.
Troubleshooting Error Source Solution Table does not No power supply Plug in the power cord move if necessary check the connections on the control unit None or a loose Verify the plug connections of the connection to the motor cable to the control unit and drives the drives, respectively establish it.
Error Code in the display of the handset (optional) Display Source Remedying The control unit monitors Wait until the "HOT" goes out, then the the duty cycle (time- table is working properly again. controlled) and its max. temperature. A value has been exceeded.
Page 17
Display Source Remedying Overcurrent Control unit - Overall current overload External sensor or the External sensor or other add-on module cable is not connected is not connected. Check the plug connection if necessary Authentication error Reset the table. Overcurrent or short circuit If errors occur during the drive.
Technical Data General Power supply 230 V ±10% / 50 Hz Standby power consumption, primarily <0.6 W no condensation 0-35° C Allowed relative humidity (for operation) 5-85% (no condensation) Allowed relative humidity (for storage) 5-90% (no condensation) Protection class (2 min. on / 18 min. off) 1 Drive with COMPACT-2 ≈...
Tests and Certifications The drive system is tested according to the following standards: Electromagnetic compatibility (EMC Directive 2004/108/EC) EN 61000-6-2:2005 Electromagnetic compatibility (EMC) EN 61000-6-3:2007 Electromagnetic compatibility (EMC) Electrical Safety (Low Voltage Directive 2006/95/EC) EN 50366:2003 + A1:2006 Electrical apparatus for household and similar purposes Electromagnetic Fields EN 60335-1:2002 + A1:2004 Safety of electrical equipment for...