Alignments and Adjustments (Mechanical)
6. Play back the Mono Scope alignment tape (SP mode).
7. Connect an oscilloscope CH-1 to the Envelope and CH-2 to the HÕD SW Pulse for triggering.
8. Turn the guide roller heads with a flat head (
) driver to obtain a flat video RF envelope as shown in
Fig. 4-67.
9. After the adjustment is completed, tighten the set screws.
IDEAL ENVELOPE
L HEIGHT
L HEIGHT
R HEIGHT
R HEIGHT
TOO HIGH
TOO LOW
TOO HIGH
TOO LOW
GUIDE ROLLER (L)
GUIDE ROLLER (R)
Fig. 4-67 S, T-Guide Roller Height Adjustment