Download Print this page

Nikon Callaway ID Tech Instruction Manual page 2

Laser rangefinder

Advertisement

Nikon Callaway id TECH / Measurement and Display
External display and contents
[Power On]
After the power is turned on, the internal
and external LEDs are illuminated until
either the POWER or MODE button is
pressed.
[Power off notice]
If 30 seconds pass without operation, the
power turns off. Approx. one second
before power turns off, this screen is
displayed.
Measuring procedures and internal display
【0 • 1 • 2】 Power On/Off and others
Operation/Results
Work
0
Switch for FULL/Limited
Perform this operation
modes
when power is off.
Operation is complete
(1)
Initial screen
When switching to Limited mode
When the symbol (shown on right) does not appear,
Limited mode is switched to Full mode.
After approx. two seconds, proceed to (2).
(2)
Measurement standby
1
Power On
Initial screen
Measurement standby
When this symbol (shown on right)
does not appear, Limited mode is set.
Measurement standby
(1)
Linear distance【3】
2
Selecting and setting
Limited mode
(2)
Horizontal distance【4】
(3)
Height (from horizontal)【5】
The angles and heights
between two points are
(4)
Angle (from horizontal)【6】
displayed only at the FULL
mode setting.
Linear distance, Horizontal
(5)
Vertical separation (height between two points) 【7】
distance and height are
displayed when FULL/Limited
mode is set.
Return to 2-(1) Linear distance, then repeat.
See the relevant section in this manual for each mode setting and display.
Regardless of process, after 30 seconds
8
Power off
since your last operation, power turns off.
【3】 Linear distance mode
Operation/Results
Work
3 Measurement with Linear distance mode
3-1
Seeking your target
Linear distance
(Align the reticle with target)
3-2
Measurement
With the POWER button depressed, continuous measurement
(Laser irradiate symbol is displayed.)
is possible for up to 20 seconds. (When done, 3-3 display appears.)
3-3
Failure to measure
Repeat step 3-1.
3-4
Measurement OK
Linear distance
Follow by 3-5 or 3-.1
3-5
Data display after
(1)
Horizontal distance【4】
witching modes
(2)
Height (from horizontal)【5】
Switching the measurement
unit changes it for each
mode. The POWER button
(3)
Angle (from horizontal)【6】
can be used to measure in
each mode.
(4)
The angle and vertical
Vertical separation (height between 2 points)【7】
separation (height between
two points) are displayed
when set at FULL mode.
(5)
Linear distance
Limited mode shows linear
distance, horizontal distance
and height.
Return to 3-5-(1) and repeat.
(In Limited mode, return to 3-5-(1), then repeat (1),(2) and (5))
Regardless of process, after 30 seconds
8
Power off
since your last operation, power turns off.
【4】 Horizontal distance mode
Operation/Results
Work
4
Measurement with horizontal distance mode
4-1
Seeking your target
Horizontal distance
(Align the reticle with target.)
4-2
Measurement
With the POWER button depressed, continuous measurement
(Laser irradiate symbol is displayed.)
is possible for up to 20 seconds. (When done, 4-3 display appear)
4-3
Failure to measure
Repeat step 4-1.
4-4
Horizontal distance
Measurement OK
Follow by 4-5 or 4-1.
4-5
Data display after
(1)
Height (from horizontal)【5】
switching modes
Switching the measurement
(2)
Angle (from horizontal)【6】
unit changes it for each
mode. The POWER button
can be used to measure in
(3)
each mode.
Vertical separation (height between two points)【7】
The angle and vertical
separation (height between
(4 )
Linear distance【3 】
two points) are displayed
when set at FULL mode.
(5)
Horizontal distance
Limited mode shows linear
Return to
distance, horizontal distance
4-5-(1), then repeat.
and height.
(In Limited mode, return to 4-5-(1), then repeat (1), (4) and (5))
Regardless of process, after 30 seconds
8
Power off
since your last operation, power turns off.
1 Point Measurement
[Results]
After measurement, all data "linear
distance, horizontal distance, height and
angle" are displayed. Units can be shown
in meters, yards or feet. Angles are
indicated by
Linear distance
Horizontal distance
Height
Angle
Unit
[While measuring]
When the target is upward
[Measurement unsuccessful or unable to measure]
When the target is upward
[Measurement complete]
When the target is upward
Button
Display
Display examples
MODE
+(follow by) POWER
Initial screen (FULL mode)
Last use symbol
All symbols (while pressing)
POWER
Last Use mode symbol
n/a
MODE
n/a
MODE
n/a
MODE
n/a
MODE
n/a
blinks.
n/a
30 seconds
without operation
Display examples
Button
Display
meter
yards
feet
Elevation(°) Depression(°)
POWER
206
225 676
MODE
201
220 660
MODE
45.0 49.2 146
MODE
13
-13
MODE
blinks
MODE
206
225 676
MODE
30 seconds
without operation
Display examples
Button
Display
meter
yards
feet
Elevation(°)
Depression(°)
POWER
201
220 660
MODE
45.0
49.2 146
MODE
13
-13
MODE
blinks
MODE
206
225 676
MODE
201
220 660
MODE
30 seconds
without operation
°
(degree).
[ m ] : meter
[ YD ] : yards
[ f t ] : feet
When the target is downward
When the target is downward
With negative values,
the "– (minus)" symbol is not shown.
When the target is downward
【5】 Height mode
Operation/Results
5
Measurement with height mode
5-1
Seeking your target
(Align the reticle with target)
5-2
Measurement
(Laser irradiate symbol is displayed.)
5-3
Failure to measure
5-4
Measurement OK
5-5
Data display after
(1)
switching modes
(2)
Switching the measurement
unit changes it for each
mode. The POWER button
(3)
can be used to measure in
each mode.
See the relevant section.
(4)
The angle and vertical
separation (height between
(5)
two points) are displayed
when set at FULL mode.
Limited mode shows linear
distance, horizontal distance
and height.
8
Power off
【6】 Angle mode
Operation/Results
6
Measurement with angle mode setting (only at FULL mode setting)
6-1
Seeking your target
(
Align the reticle with target.)
6-2
Measurement
(Laser irradiate symbol is displayed.)
6-3
Failure to measure
6-4
Measurement OK
6-5
Data display after
switching modes
(1) Vertical separation between two points【7】
Switching the measurement
(2)
unit changes it for each
(3)
mode. The POWER button
can be used to measure in
(4)
each mode
See the relevant section.
(5)
8
Power off
【7】 Vertical separation (height between two points) mode
Operation/Results
7
Measurement with Vertical separation (height between two points) mode (only at FULL mode setting)
7-1
Seeking your target
(Align the reticle with target)
7-2
Measurement
(Laser irradiate symbol is displayed)
7-3
Failure to measure
7-4
Measurement OK
7-5
Data display after
(1)
switching modes
(2)
(3)
If the mode is switched, the
(4)
2nd target cannot be
measured
Switching the measurement
(5)
unit changes it for each
mode. The POWER button
can be used to measure in
(6-1)
each mode
See the relevant section.
(6-2)
7-6
Aiming (2nd target)
(Align the reticle with target)
7-7
Measurement
(Laser irradiate symbol is displayed)
7-8
Failure to measure
7-9
Measurement OK
7-10
7-11
Date display after
(1)
switching modes
(2)
(3)
Switching the measurement
(4)
unit changes it for each
mode. The POWER button
can be used to measure in
(5)
each mode
See the relevant section.
(6-1)
(6-2)
8
Power off
Measure the distance between two points
[Results]
After measuring two points, "Linear
distance to two points" and "Vertical
separation (height) and angle between
two points" are displayed. Units can be
shown in meters, yards or feet. Angles
are indicated by (degree).
Linear distance (1st point)
Linear distance (2nd point)
Vertical separation (height between two points.)
Angle of two points
Unit
[Measuring 1st point]
[Failed to measure 1st point]
(Angle measurements never fail.)
[Results of 1st point]
Measuring 2nd point
[
]
[Failure to measure 2nd point]
(Although the point is located
(Angle measurements never fail.)
downward, display shows the
upward position.)
[Display of results for two points]
Work
Button
Height (from horizontal)
With the POWER button depressed, continuous measurement
POWER
is possible for up to 20 seconds. (When done, 5-3 display appear)
Repeat step 5-1.
Linear distance
Follow by 5-5 or 5-1.
Angle(from horizontal) 【6】
MODE
MODE
Vertical separation (height between two points)【7】
Linear distance【3】
MODE
Horizontal distance【4】
MODE
Height (from horizontal)
MODE
Return to 5-5-(1) and repeat.
MODE
(In Limited mode, return to 5-5-(3),
then repeat (3), (4) and (5).
Regardless of process, after 30 seconds
30 seconds
since your last operation, power turns off.
without operation
Work
Button
Angle (from horizontal)
With the POWER button depressed, continuous measurement
POWER
is possible for up to 20 seconds. (When done 6-3 display appears)
Repeat step 6-1.
Angle (from horizontal)
Follow by 6-5 or 6-1.
MODE
Linear distance【3】
MODE
Horizontal distance【4】
MODE
Height (from horizontal)【5】
MODE
Angle (from horizontal)
MODE
Return to 6-5-(1), then repeat.
Regardless of process, after 30 seconds
30 seconds
since your last operation, power turns off.
without operation
Work
Button
Vertical separation (height between two points)
(1st target)
POWER
Follow by 7-1
Repeat 7-1, 7-2, 7-3 until measurement is complete.
Height of 1st target (from Horizontal)
followed by 7-5 or 7-6.
Linear distance (1st target)【3】
MODE
Horizontal distance (1st target)【4】
MODE
Height (from horizontal) (1st target)【5】
MODE
Angle (from horizontal) (1st target)【6】
MODE
Vertical separation (height between two points)
MODE
7-5-(follow by 6-1 or 6-2)
Return to 7-5-(1), then repeat.
MODE
follow by 7-3 or 7-4
After aiming, POWER
Vertical separation (height between two points)
(2nd target)
(Result shown is the height of the 1st target)
POWER
Follow by 7-6
Repeat 7-6,7-7 and 7-8 until measurement is complete
Vertical separation (height between two points)
After 2 seconds move to7-10
Vertical separation (height between two points)
Follow by 7-11 or 7-1
Linear distance (2nd target)【3】
MODE
Horizontal distance (2nd target)【4】
MODE
Height (from horizontal) (2nd target)【5】
MODE
Angle (from horizontal) (2nd target)【6】
MODE
Vertical separation (height between two points)
MODE
Follow by 7-11-(6-1) or 7-11-(6-2)
Return to 7-11-(1), then repeat
MODE
Follow by 7-3 or 7-4
After aiming POWER
Regardless of process, after 30 seconds
30 seconds
since your last operation, power turns off.
without operation
Display examples
Display
meter
yards
feet
Elevation(°) Depression(°)
45.0 49.2 146
13
-13
blinks
206
225 676
201
220 660
45.0 49.2 146
Display examples
Display
meter
yards
feet
Elevation(°) Depression(°)
13
-13
5.2
-5.2
blinks
206
225 676
201
220 660
45.0 49.2 146
13
-13
Display examples
Display
meter
yards
feet
Elevation(°) Depression(°)
blinks
blinks
104
114 341
blinks
247
270 810
224
245 735
104
114 341
25
0.0
0.0
0.0
blinks
blinks
104
114 341
blinks
64.0 70.0 210
64.0 70.0 210
blinks
228
249 898
224
245 735
40.0 43.8 131
10
64.0 70.0 210
blinks

Advertisement

loading