Technische Daten

Gebläsemotor ............ 1100 Watt
max..... 1300 Watt
Unterdruck................... 225 mbar
(2300 mm WS)
Luftmenge.................... 50 dm
Filtertüte....................... 5,3 dm
Arbeitsbreite................. 448 mm
Bürstenantrieb.............. Zahnriemen
Bürstendrehzahl........... 2700 U/min
Bodenanpassung......... automatisch
sensorgesteuert
Anschlußleitung ........... 12,2 Meter
Gewicht........................ 7,7 kg
Isolationsklasse............ II, doppelt isoliert
Arbeiten an der elektrischen Installation dürfen nur
von Sachkundigen ausgeführt werden.

Technical Details

Vacuum motor ............. 1100 Watt
max...... 1300 Watt
Air flow.......................... 50 l / s
Dust bag....................... 5,3 litres, 3-layer
Working width............... 448 mm
Brush drive................... tooth belt
Brush speed................. 2700 rpm
Floor adjustment.......... automatically
sensor advised
Cable............................ 10 m
Weight.......................... 7,7 kg
Protection..................... double insulated
For service please contact your supplier or the
address below.
ACHTUNG - Hinweise zur Sicherheit
- elektrisches Gerät, vor Wasser und
Feuchtigkeit schützen
- gemäß der Anschlußwerte des
Typenschildes, anschließen und betreiben,
- nur zur Reinigung trockener Flächen,
nichts Glühendes oder Heißes aufsaugen,
- niemals bei angeschlossenem oder laufen-
dem Gerät an die Bürste fassen,
3
/ s
- Benutzung durch Kinder nur unter Aufsicht,
3
, 3-lagig
- Menschen oder Tiere nicht absaugen,
- Gerät mit Defekten nicht anschließen,
- wenn das Gerät selbst abschaltet, erst aus-
schalten, dann Netzstecker ziehen und erst
dann die Ursache beseitigen,
- bei allen Arbeiten am Gerät, ausschalten
und Netzstecker ziehen,
- nach der Benutzung den Netzstecker
ziehen,
- keine Schrauben lösen, Arbeiten im Geräte-
inneren nur durch Fachkräfte,
- Garantieleistungen nur bei Verwendung von
Original Columbus Ersatz- und
Verschleißteilen,
- Benutzung auf eigene Verantwortung, der
Hersteller kann für Schäden durch die
Benutzung nicht verantwortlich gemacht
werden,
- gemäß der Gebrauchsanweisung benutzen
und deren spezielle Hinweise beachten.
G .Staehle G mbH u. Co. K G
columbus Reinigungsmaschinen
Postfach 500960
70339 Stuttgart
Mercedesstr. 15
70372 Stuttgart
Telefon: 0711/9544-950
Telefax: 0711/9544-941
CAUTION - Safety advice
Do not re-use bags.
Do not wash filters.
Do not vacuum hot material eg. ash.
Do not leave machine near heat source eg.
fires, ovens, radiators.
Do not remove any screws.
ELECTRICAL APPLIANCE:
Disconnect from mains before maintenance
or changing brush, bag and filters.
Keep away from liquid or moisture.
Vacuum dry surfaces only.
Do not use with a damaged cable.
THIS APPLIANCE HAS A ROTATING BRUSH:
Do not run over mains cable.
Do not leave plugged in and unattended.
Children and pets must be strictly supervised
during use. Ensure machine is in upright position
and the brush is above floor level when using
the hose.
Do not tilt the brush head on to the floor when
using the hose. This can cause marking.
Do not place brush head over rug / carpet edges.
Some floor coverings may be damaged by
upright vacuums eg. wool loop carpets and
cushion vinyl. Check with flooring supplier before
use and treat with care.
IT IS THE USERS RESPONSIBILITY TO OPERATE
THIS APPLIANCE IN ACCORDANCE WITH THE
OPERATING INSTRUCTIONS.
06762 - 06.2002

Advertisement

loading
Need help?

Need help?

Do you have a question about the Bürstsauger XP3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Columbus Bürstsauger XP3

  • Page 1: Technische Daten

    Arbeiten an der elektrischen Installation dürfen nur - Garantieleistungen nur bei Verwendung von the hose. von Sachkundigen ausgeführt werden. Original Columbus Ersatz- und Do not tilt the brush head on to the floor when Verschleißteilen, using the hose. This can cause marking.
  • Page 2 Die Sicherheitshinweise beachten. use the machine before reading the Cautions. Gebrauchsanweisung INSTRUCTION MANUAL Dieser Columbus XP3 Bürstsauger ist auf hohe Your Columbus XP3 vacuum cleaner is designed Leistung, Benutzerfreundlichkeit und to give you excellent performance and long life. Langlebigkeit ausgelegt. Eine rotierende Reading this manual will help you get the most Bürste mit automatischer Höheneinstellung im...
  • Page 3 Die automatischen Funktionen Ihres The machine has an information display on Columbus XP3 Bürstsauger können Sie the power head with four lights to monitor the anhand von vier Leuchtanzeigen auf dem automatic functions. Gerätefuß überwachen. The two green lights (a, b) indicate the brush Die Automatik mißt die Leistung der Bürste...
  • Page 4 The used paper bag can be sealed with a cap, Columbus XP3 Filtertütenpackung beiliegen which is included with each bag in the (Art.-Nr. 20599900). Columbus Paper bag ( Part.-No. 20599900 ). DO NOT RE-USE PAPER BAGS. Mikrofilter und Abluftfilter wechseln Der Columbus XP3 hat zwei zusätzliche Filter,...