SAFETY PRECAUTIONS

• Installation must be made in accordance with the installation manual by qualified ser-
vice personnel.
Incorrect work will cause electric shock, water leak, fire.
• Be sure to use the attached accessories parts and specified parts for installation.
Use of other parts will cause electric shock, water leak, fire, the unit falling.
• The appliance shall be installed in accordance with national wiring regulations.
Wrong connection can cause overheating or fire.
• After installation has complete, check that there is no leakage of refrigerant gas.
If the refrigerant gas contact with fire, it may generate toxic gas.
• Ventilate the room if refrigerant gas leaks during installation.
If the refrigerant gas contact with fire, it may generate toxic gas.
• Use the specified electrical cable.
Make sure the cable is secured in place and that the terminals are free of any excess force
from the cable. Otherwise overheating or fire may result.
• Form the cable so that the control box cover, the cord holder and cable holder are not
loose.
Otherwise overheating, fire or electric shock may result.
ACCESSORIES
ITEMS
Q'ty
1 MOUNTING PLATE
To mount the indoor unit on the
1
wall.
2 WALL PLUG
To fix the mounting plate with
the long screws. (7)
9
To fix the remote control with
the special screw. (2)
3 LONG SCREW
To fix the mounting plate with
(M4.5x30)
7
the wall plugs.
4 REMOTE CONTROL
1
To control remotely.
NOTES ON LOCATIONS
Indoor unit
1. Keep the air outlet clear of any obstacle
so that outgoing air flows smoothly in
the entire room.
2. Make a drain hose hole for easy drain-
age.
3. Provide sufficient space on both sides
and above the unit.
4. The air filters should be easily taken in
and out.
5. Keep TV set, radio and the like 1 m or
more away from the unit and the remote
control.
6. Keep the air inlet clear of obstacles that
could block incoming air.
7. The remote control may not function
properly in a room equipped with an
electronic simultaneous-start or rap-
id-start fluorescent lighting.
8. Select a location that does not cause
loud operation noise and extreme vibra-
tions.

INSTALLATION DIAGRAM

1
MIN.50
3
3
MIN.50
MIN.100
MIN.200
EHP8.5AA_final all.indd 2
SPLIT AIR/AIR
HEAT PUMP

INSTALLATION MANUAL

APPLICATION
ITEMS
5 DRY BATTERY
6 SPECIAL SCREW
(Black)
7 TERMINAL COVER
8 SHORT SCREW
(M4x12)
Outdoor unit
1. Place the outdoor unit on a stable base.
2. Provided sufficient space around the unit. It should also be
well ventilated.
3. The unit should not be exposed to strong wind nor
splashed with rain water.
4. Water drain from the unit should be let out without prob-
lem. Lay a drain hose if required. In cold regions, install-
ation of the drain pipe is not advisable as freezing could
result.
5. Keep TV set, radio and the like 1 m or more away from the
unit.
6. Avoid locations exposed to machine oil vapor, salty air
(facing the seashore, for example), hot spring vapor sulfur
gas, etc. Such location can cause breakdown.
7. Also, avoid locations exposed to muddy water (along a
road, for example) or where the unit can be tampered with.
8. Select a location where the outgoing air or operating noise
cannot annoy others.
9. Keep the air outlet opening free of any obstacle. This could
affect the performance of the unit and create loud noises.
(Recommended more than 100 mm)
MIN.50
MIN.120
MIN.20
Open panel
Provide as much installation
space as possible for efficient
air-conditioning.
MIN.200
Length unit: mm
Indoor Unit
Outdoor Unit
EHP 8.5 AA/I
EHP 8.5 AA/O
• Tighten the flare nut with a torque wrench according to the specified method.
If the flare nut is tightened too hard, the flare nut may be broken after a long time and cause
refrigerant gas leakage.
• When installing the unit, take care not to enter air substance other than the specified refri-
gerant(R410A) in the refrigerant cycle.
Otherwise, it will cause burst and injury as a result of abnormal high pressure in the refrigerant cycle.
• Be sure to connect the refrigerant pipe before running the compressor.
Otherwise, it will cause burst and injury as a result of abnormal high pressure in the refrigerant cycle.
• Earth the unit.
Incomplete earth may cause electrical shock.
• If national legislations or type of installation requires earth leakage breaker, the legislation
must be followed.
• Arrange the drain hose to ensure smooth drainage.
Insufficient drainage may cause wetting of the room, furniture etc.
• This room air conditioner uses refrigerant R410A.
Use the pipe, flare nut and tools exclusively for R410A.
Q'ty
APPLICATION
For the remote control.
2
AAA batteries.
• To mount the remote control
on the wall.
2
• To mount the remote
control holder on the wall.
1
To cover the electrical cable.
1
To secure the terminal cover.
PIPING
Max. piping length: A
15 m
• Additional refrigerant charge is not neccessary.
• Standard piping length is 5m.
• When the outdoor unit is placed at a higher level than the indoor unit, provide a trap near the
hose's lead-in port.
Use the refrigerant pipes shown in the table below.
Pipe size
Liquid side
Gas side
The thermal insulation should cover both the gas and liquid pipes.
NOTES ON DRAIN HOSE
The drain hose can be connec-
ted at either side of the indoor
unit.
Reposition the drain hose and
drain cap as required.
MIN.50
(1) Remove the fixed screw in the
hose holder at the end of the
drain hose.
(2) Hold the end of the drain hose,
and pull it out.
(3) Pull out the drain cap.
(4) Reconnect the drain hose to
MIN.120
the right and insert the drain
cap to the left.
• Fully insert the drain hose until it
stops and use the screw that was
previously removed in STEP(1)
to secure the hose holder to the
drain pan.
• Insert a hexagon socket screw
key (4 mm diagonal) into the
drain cap, and press it fully.
Caution:
After replacing, make sure that both
the drain hose and drain cap are
firmly inserted.
2
ITEMS
Q'ty
APPLICATION
9 REMOTE CONTROL
To mount the remote control on the
HOLDER
wall.
1
10 MANUALS
Installation manual
1
Operation manual
1
11 AIR PURIFYING FILTER
To remove dust and tobacco
smoke from the air.
2
12 SHEET(adhesive type)
To firmly secure the electrical cable.
1
Max. height difference: B
10 m
Pipe thickness
1/4" (ø 6.35 mm)
Thickness: 6 mm or thicker
0.8 mm
Material: Polyethylene foam
3/8" (ø 9.52 mm)
Indoor Unit
A
B
Outdoor Unit
Drain cap
Screw
(2)
(1)
Hose holder
(3)
Drain cap
(4)
Drain hose
(4)
Drain cap
B593
Min. piping length
3 m
Thermal insulation
B
Trap
Drain hose
Drain hose
Hexagon socket
screw key