Hi-Power Mode; Discharge Temperature Control; Quiet Mode - Carrier 42UQV050M Service Manual

Split type
Hide thumbs Also See for 42UQV050M:
Table of Contents

Advertisement

Item
14. Hi-POWER
([
Mode
is pressed)
When [Hi-POWER]
indoor unit is in Auto, Cooling or Heating operation,
Hi POWER mark is indicated on the display of the
remote controller and the unit operates as follows.
1. Automatic operation
• The indoor unit operates in according to the
2. Cooling operation
• The preset temperature drops 1 degree
3. Heating operation
• The preset temperature increases 2 degree
4. The Hi-POWER mode can not be set in Dry
operation

15. Discharge temperature control

Td value
Judges as an error and stops the compressor.
117°C
Reduce the compressor speed.
112°C
Reduce slowly compressor speed.
108°C
Keeps the compressor speed.
105°C
If the operation is performed with lower speed than one
commanded by the serial signal, speed is slowly raised
up to the commanded speed.
98°C
Operates with speed commanded by the serial signal.

16. QUIET mode

When the [
the indoor unit will be restricted the revolving
speed at speed L - until the [
pushed once again (cancel Quiet mode).
Operation flow and applicable data, etc.
] button on the remote controller
button is pressed while the
current operation.
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
Control operation
] button is pushed, the fan of
1. Purpose
This function detects error on the
refrigerating cycle or error on the com-
pressor, and performs protective control.
2. Operation
• Control of the compressor speed
Quiet mode is the system which, control the
revolving speed of indoor fan to work constantly
] button is
at lower than speed L. In addition, noise level of
indoor unit is less than usual.
Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less
cooling load and less heating load condition.
Because of the fan speed L- may cause not
enough the cooling capacity or heating
capacity.
38
FILE NO. SVM-13035
Description
The speed control is performed as
described in the left table based upon
the discharge temperature.