This water heater must only be installed by a qualified installer / service technician. Read all instructions in this manual
before installing. Perform steps in the given order. Failure to do so could result in substantial property damage, severe
personal injury, or death.
California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.
The manufacturer reserves the right to make product changes or updates without notice and will not be held liable for
typographical errors in literature.
The surfaces of these products contacted by potable (consumable) water contain less than 0.25% lead by weight as required
by the Safe Drinking Water Act, Section 1417.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
272 Duchaine Blvd.
Electric Water Heaters
New Bedford, MA 02745
Everlast
Grid Enabled
www.htproducts.com
lp-608 Rev. 000 Rel. 001 Date 3.15.18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EVG080C2X045H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HTP EVG080C2X045H

  • Page 1 Everlast Grid Enabled Electric Water Heaters Use and Care Manual Installation Start-Up Maintenance Parts Warranty This water heater must only be installed by a qualified installer / service technician. Read all instructions in this manual before installing. Perform steps in the given order. Failure to do so could result in substantial property damage, severe personal injury, or death.
  • Page 2: Table Of Contents

    B. Enabling the Lower Element officer or departmental official may be the AHJ. C. Field Wiring Details NOTE: HTP reserves the right to modify product technical specifications Part 5 - Installation Checklist and components without prior notice. Part 6 - Operation A.
  • Page 3: When Servicing The Water Heating System

    not result in damage to the surrounding area. If such a location is B. Heater Water not available, install an auxiliary catch pan. Do not use petroleum-based cleaning or sealing compounds in a water heating system. Gaskets and seals in the system may be damaged. This can result in substantial property damage.
  • Page 4: Part 2 - Prepare The Water Heater

    possible to read or view some product labeling. It is recommended to make note of the water heater model and serial number. NOTE: A combustible door or removable panel is acceptable front clearance. The service life of the water heater’s exposed metallic surfaces, such as the junction box, is directly influenced by proximity to damp and salty marine environments.
  • Page 5: Water Chemistry Requirements

    NOTE: If you do not provide the minimum clearances shown in • Hardness less than 12 grains (200 mg/L) (Residential Use - Figure 1, it might not be possible to service the water heater without water temperatures below 140 removing it from the space. • Hardness levels above the required amounts can lead to lime scale build-up throughout the system.
  • Page 6 Safety Models Cold Delivered Delivered Temp. Weight Capacity Listing Inlets (Lbs. Est.) Temp. Temp. Limit EVG080C2X045H 6 1/2” 69” 23 1/4” 60” 27” 3/4” EVG100C2X045H 61” 52” 8” UL 174 (43.3 C) (76.6 C) (87.8 C) 7 1/4” 27” 30 3/4”...
  • Page 7 HOT OUTLET HEAT TRAP COLD DIP TUBE INSERTION INSERTION POINT POINT TOP VIEW LP-608-C 11/15/16 Figure 3 - Installing Cold Inlet and Hot Outlet Fittings CAUTION The Cold Inlet and Hot Outlet Fittings MUST BE INSTALLED according to the steps in Figure 3 for the electric water heater to operate properly.
  • Page 8: Part 3 - Piping

    the cold water inlet line. Contact your installing contractor, water Part 3 - Piping supplier, or plumbing inspector for additional information regarding thermal expansion. A. Plumbing C. Condensation It is mandatory that all plumbing be done in accordance with federal, Condensation can form on the water heater when it is first filled with local, and state plumbing codes and practices.
  • Page 9: Scalding

    F. Scalding To avoid water damage or scalding due to relief valve operation: • Discharge line must be connected to relief valve outlet and Mixing valves are recommended for reducing point of use water run to a safe place of disposal. Terminate the discharge line temperature by mixing hot and cold water in branch water lines.
  • Page 10: Applications

    H. Applications Part 4 - Wiring TO ELECTRICAL A. Communication DISTRIBUTION PANEL ELECTRICAL JUNCTION NOTE: 80 gallon and larger water heaters are locked per Federal Regulations. The water heater is intended to be used for thermal VACUUM BREAKER energy storage by the utility. See Figure 8 for a detail of the lock. UNION Contact the utility to unlock the box, enable the lower element, and HEAT TRAP...
  • Page 11 Figure 5 - Unlocking the Lower Element Figure 6 - Water Heater and Control Wiring lp-608 Rev. 000 Rel. 001 Date 3.15.18...
  • Page 12: Part 5 - Installation Checklist

    Part 5 - Installation Checklist Failure to disconnect the power from the water heater before Water Heater Location attempting to adjust or reset the thermostat will result in property damage, severe personal injury, or death. Close to area of heated water demand Indoors and protected from freezing TO ADJUST THE UPPER temperatures...
  • Page 13: Lower Thermostat Adjustment

    C. Lower Thermostat Adjustment Step #5 - Replace the element protective cover, enclosure insulation, and lower cover with gasket. Failure to disconnect the power from the water heater before Step #6 - Reinstall the lock box with the three (3) screws. Reinstall the attempting to adjust or reset the thermostat will result in property wires at the screw terminal locations.
  • Page 14: Part 7 - Maintenance

    DO NOT replace heating element with a generic heating element. this water heater should be inspected annually by a qualified service Only HTP heating elements are approved for use with this water technician to assure that all the equipment is operating safely and efficiently.
  • Page 15 Periodically (At least twice a year) Check around the water heater and related plumbing for leaks. If the combination temperature and pressure relief valve discharges T&P Relief Valve Maintenance Instructions: periodically, or water is leaking from around the heating elements, •...
  • Page 16: Part 8 - Troubleshooting

    Part 8 - Troubleshooting Problem Reason Remedy Manual disconnect switch turned off Turn switch on Diagnose system for possible short circuit or Blown fuse or circuit breaker tripped malfunction. Replace fuse or reset breaker. Circuit overload Provide adequate circuit for load Grounded element or thermostat Repair or replace defective part(s) No Hot Water...
  • Page 17: Part 9 - Replacement Parts

    Part 9 - Replacement Parts Figure 10 - Replacement Parts - Staged Operation lp-608 Rev. 000 Rel. 001 Date 3.15.18...
  • Page 18: Limited Warranty

    Owner. Stainless Steel Electric Water Heater H. HTP will not accept claims from the Owner for labor costs incurred by Limited Warranty any person as a result of the repair, replacement, removal, or reinstallation of a water heater or any component thereof.
  • Page 19 During the claims process a product that must be replaced will be given a designation of either a) field scrap, or b) return to HTP. If the product must be returned to HTP, the returned product must arrive at HTP within thirty...
  • Page 20: Customer Installation Record Form

    Customer Installation Record Form The following form should be completed by the qualified installer / service technician for you to keep as a record of the installation in case of a warranty claim. After reading the important notes at the bottom of the page, please also sign this document. Customer’s Name Date of Installation Installation Address...

This manual is also suitable for:

Evg100c2x045hC2x045hEvg115c2x045hC2x055h

Table of Contents