Page 1
California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.
Page 2
AHJ. motion. Strapping shall be at points within the upper one-third NOTE: HTP reserves the right to modify product technical specifications (1/3) and lower one-third (1/3) of its vertical dimensions. At the and components without prior notice.
Table of Contents Part 1 - General Safety Information A. When Servicing the Water Heating System High heat sources (sources generating heat 100 F / 37 C or greater, B. Heater Water such as stove pipes, space heaters, etc.) may damage plastic C.
Approximate Time / Temperature Relationships in Scalds More than 5 minutes This water heater must be installed upright in the vertical position 1 1/2 to 2 minutes as described in this manual. DO NOT attempt to install this water heater in any other orientation. Doing so will result in improper About 30 seconds water heater operation and property damage, and could result in About 10 seconds...
• Maintain water pH between 6.5 and 8.5. Check with litmus paper or have it chemically analyzed by a local water treatment company. • If the pH is not between 6.5 and 8.5, consult a local water treatment company for solutions. •...
Page 6
Front View Top View LP-379-J 07/13/15 Figure 2 - Dimensional Drawing - Non-Simultaneous Operation Specifications and Dimensions Water Temperature Ratings Light Hot / Shipping Min. Max. High Storage Safety Commercial Cold Weight Delivered Delivered Temp. Capacity Listing Models Inlets (Lbs. Est.) Temp.
Page 7
Figure 3 - Installing Cold Inlet and Hot Outlet Fittings CAUTION The Cold Inlet and Hot Outlet Fittings MUST BE INSTALLED according to the steps in Figure 3 for the electric water heater to operate properly. Failure to install these fittings properly will result in improper water heater operation, possible substantial property damage, and increased costs.
the cold water inlet line. Contact your installing contractor, water Part 3 - Piping supplier, or plumbing inspector for additional information regarding thermal expansion. A. Plumbing C. Condensation It is mandatory that all plumbing be done in accordance with federal, Condensation can form on the water heater when it is first filled with local, and state plumbing codes and practices.
F. Scalding To avoid water damage or scalding due to relief valve operation: • Discharge line must be connected to relief valve outlet and An ASSE 1017 or ASSE 1070 temperature limiting or mixing valve is run to a safe place of disposal. Terminate the discharge line recommended in installations servicing disabled or elderly persons, in a manner that will prevent possibility of severe burns or or children.
H. Applications Figure 5 - Sealing the Water Heater for Sanitary Applications Part 4 - Wiring Tank must be full of water before the power is turned on. Heating elements will be damaged if energized for even a short time while tank is dry.
Part 5 - Installation Checklist Water Heater Location Close to area of heated water demand Indoors and protected from freezing temperatures Area free of flammable vapors Provisions made to protect area from water damage and control thermal expansion Sufficient room to service heater Relief Valve Temperature and Pressure Relief Valve prop- erly installed and discharge line run to open...
DO NOT replace heating element with a generic heating element. Step Replace Only HTP heating elements are approved for use with this water insulation. heater. Failure to follow this warning will result in premature Step #6 - Reattach the access product failure and VOID the warranty.
NOTE: Repeat Steps 3 - 6 as Necessary for Multiple Elements To flush the tank, attach a hose to the field installed drain valve. Close Step #8 - Open the main cold water inlet. If the water heater has the cold water supply line shut-off valve. Open the drain valve and hot been isolated from the system, open the valves.
Page 14
T&P Relief Valve Maintenance Instructions: • Annually: Certain naturally occuring mineral deposits may adhere to the valve, blocking waterways and rendering the valve inoperative. The T&P Relief Valve lever must be operated to ensure the waterways are clear. If waterways are clear, hot water will discharge from the valve.
Part 8 - Troubleshooting Problem Reason Remedy Manual disconnect switch turned off Turn switch on Blown fuse or circuit breaker tripped Replace fuse or reset breaker Shorted or improper wiring *Replace, repair, or rewire per detail Circuit overloaded *Provide adequate circuit to reduce load Grounded element or thermostat *Replace No Hot Water...
9. Any failed components of the system not manufactured by HTP as part of with the above warranty, HTP reserves the right to refund to the Owner the water heater.
Page 17
During the claims process a product that must be replaced will be given a 15. Damages, malfunctions, or failures caused by improper wiring conversion. designation of either a) field scrap, or b) return to HTP. If the product must 16. Damages, malfunctions, or failures resulting from vacuum conditions.
Customer Installation Record Form The following form should be completed by the Qualified Installer / Service Technician for you to keep as a record of the installation in case of a warranty claim. After reading the important notes at the bottom of the page, please also sign this document. Customer’s Name Date of Installation Installation Address...
Need help?
Do you have a question about the Everlast EVC080 and is the answer not in the manual?
Questions and answers