Recommended Operating Conditions

Item
Supply voltage range
Input voltage range
Output voltage range
Output current
Operating free-air temperature T
Note: Unused or floating inputs must be held high or low.
Rev.2.00, Oct.16.2003, page 4 of 9
Symbol
Min
V
3.0
CC
V
0
I
V
0
O
I
OL
I
OH
–40
a
Max
Unit
Conditions
5.5
V
5.5
V
V
V
CC
6
mA
V
= 3.0 to 3.6 V
CC
12
V
= 4.5 to 5.5 V
CC
–6
V
= 3.0 to 3.6 V
CC
–12
V
= 4.5 to 5.5 V
CC
85
°C