6. Verify the dud sensor face is parallel to the top of the can. If
necessary, use the adjusting screw to change the angle. When
complete, tighten the adjusting screw and its locknut
securely.
1
2
3
No.
1
2
3
4
Figure 4. Level the sensor bracket parallel to the container top.
7. Press Key 5 until
8. Press the Arrow Key until
of the display, and if prompted, enter the password to access
the Calibrate Mode.
9. Press Key 2 until
turned on. If not, press the Arrow Key until
inspection is now activated.
10.Press Key 2 until
listed on the bottom line. The reading marked
current dud sensor reading.
4
Description
Bracket Pivot Hinge
Bracket Leveling Adjustment Screw
Bracket is parallel with lid or cap
Direction of container flow
System Display
appears.
Calibrate
appears in the bottom line
Dud Status
appears and verify the status is
Dud Readings
appears. Four (4) readings are
Dud Inspection Operation Manual
ON
appears. Dud
C=
is the
Document 40378-0502