Error Number 111
Dud inspection windows length exceeded. Lower the Gamma
Sample Cutoff Limit or verify Container Width at Trigger. Then
perform Dud Calibrate.
Error Number 112
Dud reference diameter calibrated larger than inspection
window. Reduced reference diameter and verify container width
at trigger.
Error Number 113
Possible sliding container or high lid. dud inspection missed
leading reference. Dud Ref. Diameter may need to be decreased.
Error Number 114
Possible sliding container or high lid. dud inspection missed
trailing reference. Dud Ref. Diameter may need to be decreased.
Error Number 116
Dud calculated reference points less then 3/4 of calibrated
reference diameter. Possible raised tab, dented can, can off
centerline of sensor, or sensor too close to cap.
20
Dud Inspection Operation Manual
Document 40378-0502