Troubleshooting - Reliable I500A Instruction Manual

I500 series professional steam station
Hide thumbs Also See for I500A:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

PROBLEM
The steam from the iron
is too wet.
Water is coming out from
the boiler.
There is no steam coming out
of the iron, nozzle or gun.
The steam is dirty.
POSSIBLE CAUSES
1. While filling the tank you
may have poured too much
water into it.
2. The iron soleplate is not
getting hot enough.
1. There might be a leak in the
heating element gasket.
1. The steam knob might
be closed
2. The iron switch might be off
3. The foot pedal is not
plugged in (i500A)
4. The boiler switch might
be off
5. If the low water light is on,
the water in the tank is low
or empty.
1. When using the iron with a
ironing shoe, if not cleaned
regularly, calcium will form
between the shoe and the
iron base.
REMEDY
1. The problem will go on
until the excess water is
emptied. Keep the steam
button pressed until the
water in the tank is at the
correct level.
2. Please check that the
temperature knob is
on the right position, if
not, increase the iron
temperature.
1. Contact technical support
as in most cases, the
gasket will need to be
replaced.
1. Open the steam knob
anticlockwise.
2. After the iron switch
comes on, wait for 4 min-
utes so that the iron plate
gets hot.
3. Plug the 4-pin receptacle
into the boiler.
4. After the boiler switch
comes on, wait for 10
minutes so the boiler
produces steam.
5. Refill the boiler carefully
following the instructions.
1. Remove and rinse the
ironing shoe on a regular
(monthly) basis to avoid
scale build-up.
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I500bI500

Table of Contents