AH20 - DIP Switch Configuration Table (S101)
8
Dip
s
l
witCH
abel
n
umber
1
A0
2
A1
3
A2
4
A3
5
A4
6-8
9
INT/
10
EXT
D
esCription
Controls use of Red LED signal for access decision.
ON => Red LED is used.
OFF => Red LED is ignored.
Set to OFF by default. Reserved for future use.
Controls addition of parity bits if required.
ON => Addition of parity bits is enabled.
OFF => Addition of parity bits is disabled.
Credentials are transmitted as received.
Controls byte order of transmitted credentials.
ON => The byte order is reversed on the Wiegand
interface compared to what is received from the
Aperio
lock.
®
OFF => The byte order is left as is.
Used in "Pairing Mode".
ON => Starts in pairing mode.
OFF => Normal use.
Not applicable (only used for AH30).
Not used.
Internal/External Antenna Use, ON = Internal

Advertisement