13. Engineer Log Review
The engineer log is organised into SET and UNSET events. The log will show the first to
alarm and subsequent alarms as well as isolated circuits. First to alarm is shown by the
relevant LED being 'ON'. Subsequent alarms are shown by the relevent LED(s) flashing and
isolated circuits are shown by the relevent LED(s) pulsing slowly. The buzzer will sound whilst
reviewing the 'SET' logs and the 'DAY' LED will be 'ON' whilst reviewing the 'UNSET' logs.
To view the engineer logs proceed as follows.
From the program mode press the '5' key. The log routine will start with DAY 1 SET. The
remaining logs are viewed by pressing the relevent key '2' for 2nd, '3' for 3rd etc. on to log 9.
Pressing the '0' key gives the last to alarm condition. To exit logs press the * key.
The # key will alternate between 'SET' and 'UNSET' logs and can be used at anytime.
Exiting Engineer Mode
When all programming and testing is complete make sure the sounders, detectors and battery
are connected. Once complete the system is ready to hand over to the user. To exit engineer
(program mode) press the # key from the program mode and the system is ready. The 'mains'
LED and DAY LED will now be 'ON'.

14. Factory Defaults

The control panel can be reprogrammed with the factory defaults. To reload defaults proceed
as follows.
Power down and remove battery. Fit a link to CN6 on the control board. Repower the system.
The link can now be removed. If the reloading is successful when the system powers up there
will be a two tone buzz and this signifies correct loading of defaults.
Factory Defaults
User Code 1234
Engineer Code 7890
Circuit 1 Personal Attack (PA)
Circuit 2 Alarm Circuit
Circuit 3 Alarm Circuit, Isolate in Part Set
Circuit 4 Part Set Entry, Walk Through
Circuit 5 Full Set Entry, Part Set Entry
Full Set Exit Time 30 Seconds
Part Set Exit Time 15 Seconds
Entry Time 30 Seconds
Bell Ring Time 15 Minutes