12. Extended Programming - Gaurdall Rascal Super Engineer's Manual

Hide thumbs Also See for Rascal Super:
Table of Contents

Advertisement

This manual is from
http://groups.msn.com/UKSecurityPanels
www.thesecurityinstaller.co.uk
Part Set Exit Time
If programmed for part set the part set exit time must be programmed as follows.
From program mode press the '3'key followed by the '3' key. The time is programable from
5 - 105 seconds. Add the displayed number and multiply by 5 e.g. to set for 15 seconds press
the '3' key (LED 3 will be on). Time set is 3 multiplied by 5 = 15 seconds. Press the * key to
exit.

12. Extended Programming

Extended programming functions are in groups. These are accessed by entering 70, 71, 72,
73, 74 and 79. There are various features available within these groups. These features
either enable or disable functions. If a function is enabled the LED for that function will be ON.
If it is disabled the LED will be OFF.
To program these features proceed as follows.
Group Press key '7' followed by '0' key
1 Press Key Feature LED on for Feature
1 Part Set Disable No Part Set
2 Bell Disable No Bells in Part Set
4 Instant Set Instant Set in Part Set
* To Exit
i.e. To change from instant set from program mode, press key '7' followed by '0' key. Then
press 4 key to enable instant set (LED 4 will be on if instant set selected). Press the * key to
exit.
Group Press key '7' followed by '1' key
2 Press Key Feature LED on for Feature
1 Home Set Disable No Home Set
2 Bell Disable No Bell in Home Set
4 Instant Set Instant Set in Home Set
* To Exit
i.e. To program for bell disable from program mode, press key '7' followed by '1' key. Then
press '2' key to enable the no bell in home set featue (LED 2 will be on if no bells in home set
is selected). Press the * key to exit.
Group Press key '7' followed by '2' key
3 Press Key Feature LED on for Feature
1 Engineer Alarm reset Engineer only alarm reset
2 Engineer PA reset Engineer only PA reset
* To Exit
Group Press key '7' followed by '3' key
4 Press Key Feature LED on for Feature
1 Convert switch inputs Push Button Setting
* To Exit
Group Press key '7' followed by '4' key
5 Press Key Feature LED on for Feature
1 Flash circuit LED in Quick flash LED if circuit open
'DAY'
3 10 minute auto isolate Isolate circuits open for 10 mins
4 Blockschloss function Special setting method(Germany)
* To Exit
Bell Delay
The engineer can select bell delay as follows.
From program mode press the '7' fo
llowed by the '9'. The time is programable from 1 - 21
minutes. Each key represents a time in minutes e.g. to set for 20 minutes press the 6 key
followed by the '5', '4', '3' and '2' keys. Time is 6 + 5 + 4 + 3 + 2 = 20 minutes.
Press the * key to exit.
Note : If selected this feature will prevent the bells or sounders from operating for the selected