Specification; Initial Power Up; Circuit Programming - Gaurdall Rascal Super Engineer's Manual

Hide thumbs Also See for Rascal Super:
Table of Contents

Advertisement

This manual is from
http://groups.msn.com/UKSecurityPanels
www.thesecurityinstaller.co.uk

7. Specification

a) Power Supply
Mains Supply Voltage - 240V AC Nom
PSU I/P Voltage - 16V AC
PSU O/P Voltage - 12V Nom
Current - 750mA
AUX Current - 500mA
Batt Fuse - 1A (20mm)
b) Keypads
Supply Voltage - 12V
Current Quiescent - 20mA
Active - 45mA
Maximum cable length 100 metres.
c) General
Operating Temperature - -10°C to +50°C
Humidity - Up to 80% non condensing
Dimensions - 213mm(W) x 176mm (H) x 93mm (D)
Weight Control Panel - 1.25 (kg) excl. battery
Standby Battery - 1.9AH 12V Rechargeable lead acid

8. Initial Power UP

Following completion of all the wiring to the main control unit and remote keypad(s) the
engineer can proceed with power up of the system. Switch on the mains and proceed as
follows.
NOTE : KEEP THE COVER OFF THE MAIN CONTROL PANEL
Enter 1234 this will stop the tamper. Press the "#' key to silence the intermittent tone.
TAMPER LED will flash. 'MAINS/DAY' LED's will both be 'ON'. Enter 7890 (Engineer code).
The TAMPER and DAY LED's will extinguish and the MAINS LED will flash. The panel is now
in program mode.

9. Circuit Programming

The Rascal Super is designed to be fully programmable. The engineer should be familiar with
all the programming options available to each circuit there are six circuit types with various
options assigned to each. These are listed below.
Function Options Available
Alarm Isolate in part set
Isolate in home set
Walk through (entry route)
Chime
Isolatable (user)
Full Set Entry Walk through (entry route)
Chime
Isolatable (user)
Part Set Entry Walk through (entry route)
Chime
Isolatable (user)
Note : All entry circuits are isolated in Home Set.
Full Set Entry acts as a normal alarm in Part Set.
Part Set Entry acts as a normal alarm in Full Set.
If you require entry in both Full and Part Set select both options.
24 Hr Bells/Strobe in 'DAY'
Hurry up tone and sounder
Fire Bells/Strobe in 'DAY'
PA No options available
Important Note : Any circuit can be programed from its factory default. In order to reprogram
the original configuration must be removed. This is done by entering circuit configuration i.e.
key 4 followed by key 1 for circuit 1 then the 0 key must be pressed to erase the configuration.
If the * key is pressed before a new configuration is entered the original configuration will be
reinstalled.
To program circuits the following keys must be pressed.
Key 4 followed by 1 Circuit one options
Key 4 followed by 2 Circuit two options
Key 4 followed by 3 Circuit three options
Key 4 followed by 4 Circuit four options
Key 4 followed by 5 Circuit five options