INSTALLATION

WIRING THE FP90

Field wire main power supply to fi replace blower
system.
(All electrical connections should
only be performed by a
licensed/certifi ed
electrician).
CAUTION:
Label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
INSTALLING THE
BLOWER SYSTEMS
The FP90 Fireplace has been designed to
meet a wide range of heating requirements.
The radiant heat (through the large glass area)
combined with the naturally convected heat,
allows the FP90 Fireplace to adequately heat an
average sized room. A blower is recommended
to assist in heating a larger area or one with
wall separations.

GRAVITY AIR FEED KIT OPTION

The Gravity Air Feed Kit is designed to extend the heat output vent above the FP90 to the
front or the side. The upper louver opening is blocked off and fl ex vent is connected to the
vent holes in the top of the unit and run to discharge vent grilles. Both 8" (203mm) diameter
insulated Flex vents must be used along with one 30 sq. inch (194cm
bring additional air into the chase (for U.S. installations only).
Qty
Description
4
Connector Collars
4
Adjustable Clamps
2
5' lengths of fl exible vent pipe
(8" dia.)
2
Insulated Sleeves
1
Block Off Plate
2
Discharge Vent Mounting Frames
7
1/4-20 x 1/2" Truss Head Screws
(used for EX90/R90 only)
2
16 x 8 Discharge Vent Grilles
4
#8 Drywall Anchors
4
Insulation Strips
1
Chase Vent Frame
(not required for FP90)
1
8 x 8 Chase Vent Grille
(not required for FP90)
16
Jakel AX-2495 Blower
Plan View
Front View
Fan 910-175 AX-3088
Thermodisc 910-142 P60T12

Internal Blower with Thermo-Disc

The thermodisc provides the user with more convenient control. The fan operates automati-
cally - turn the knob to adjust to desired speed. The fan will turn on as the stove comes up to
operating temperature. After the fi re cools to below a useful heat output range the fan will shut
off automatically.
Place sticker on outside of bottom louver.
) chase vent grill to
2
Connector
Collar
Insulation
Strips
Discharge Vent
Outside Air
Grill
Intake
Chase Vent
Grill
30 sq.in. (194 sq.cm)
opening
Angle View
Fan Transfer Plate
Right View
910-903
910-516
Ground
Neutral - from Fan
Ground
919-885
Variable Switch 910-330
Ceiling
Flue
Flex Vent
Clamp
Connector
Collar
Alternate Position for
Chase Vent Grill
Power Chord 910-619
6" (152mm) Min.
To Rouch Opening
Center-line
of Vent
Vent Cover 'A"
Vent Cover 'B'
(Inside)
Base of Stove
Block-off Plate
(replace top louver)
FPI FP90 Wood Fireplace