Zero clearance direct vent gas fireplace (72 pages)
Summary of Contents for FPI FP90
Page 1
Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 918-426j 04/04/08...
Page 2
This product has been certifi ed by the Environmental Protection Agency of the United States. This means that it meets the strictest standards in providing you with the latest in clean burning technology and effi ciency. Specifi cations may vary widely. Consult with your FPI Dealer for local considerations.
Draft Control ............34 Chase Enclosure ..........11 Installation Measurements / Framing Details ....12 OPERATING INSTRUCTIONS Installing The Stand-offs ..........13 Set The Regency FP90 Into Position ......13 Installing The Chimney System ........13 First Fire ..............34 Assembly Steps ............13 Safety Guidelines ............34 Offset Chimney Installation ........14...
It is located inside the lower louver opening on the left side. We have on the unit and if there is a difference, the label on the unit is the correct printed a copy of the contents here for your review. one. SAFETY LABEL FOR FP90 FPI FP90 Wood Fireplace...
INSTALLATION READ BEFORE YOU INSTALL 6) Use solid fuel only. DO NOT use artifi cial logs 14) FPI Fireplace Products International Ltd. THE REGENCY HIGH containing petroleum products, chemical does not warranty “smoke-free” operation chimney cleaners, gas logs, gas lighters,...
DIMENSIONS AND SPECIFICATIONS The Regency is a wood burning fi replace featuring This fi replace system is designed for installation The FP90 main unit consists of the following: a self-contained heat-circulating system and cast- in accordance with the National Fire Protection iron doors with large viewing windows.
INSTALLATION CLEARANCES AND HEIGHT REQUIREMENTS The FP90 may be placed on or near construction WARNING: Do not pack or fi ll required air spaces No Combustibles on Face of Unit. with insulation or other material. No material of materials. The combustion air kit, fi re stop spacer any kind is allowed in these areas.
Nailing Strips. The Nailing Strips can also be 28 " [710mm] moved forward and back by adjusting the screws that mount them to the fi replace. 44 " [1118mm] 18 " [457mm] Building Structures Cannot Encroach on Chase FPI FP90 Wood Fireplace...
fi replace and chimney. A ventilated chase cap is highly Regency’s FP90 Fireplace is to be installed recommended. Refer to fl ue manufacturer's with one of the following Chimney Systems instructions for reduced fl ue heights above chase only.
6) MUST MAINTAIN A MIN. OF 24" (610mm) TO SIDE WALL FROM THE EDGE OF THE TOP LOUVER OPENING. 7) HEARTH MUST BE A MIN. OF 40" (1016mm) WIDE x 18" (457mm) deep and 1/2" (127MM) THICK. FPI FP90 Wood Fireplace...
2) Complete framing and installation of nailing can the fi replace top or side spacers be The minimum ceiling height is 7ft (2m) from the strips for the FP90. removed or modifi ed. Do not notch the base of the unit. A suitable non-combustible header to be installed closer than the hearth pad is mandatory in all installations.
Do not use water, it will create a steam explosion. e. Check for hot embers around the unit and outside your home; extinguish. Do not use your fi replace again until it has been inspected by a qualifi ed person. FPI FP90 Wood Fireplace...
This may cause a negative pressure in the Outside Air Inlet must be 6 ft. (152mm) below automobile exhaust, gas meters or other house allowing smoke to back into the home. the chimney termination point vents. FPI FP90 Wood Fireplace...
To Rouch Opening Flue above the FP90 to the front or the side. The upper louver opening is blocked off and fl ex vent is connected to the vent holes in the top of the unit and run to discharge vent grilles. Both 8" (203mm) Center-line diameter insulated Flex vents must be used along with one 30 sq.
Use the chase vent supplied surface area. Do not spread more than a with the FP90 unit only or any equivalent workable area so that the mortar will not one with the same or less restriction of air set up before stone or brick is applied.
Depending on the installation, heavier LEFT RIGHT reinforcing wire screen may be required to SIDE SIDE bridge the stand-off spacer area around the perimeter of the unit. Hold in position with 2 screws while the door arch is centered. FPI FP90 Wood Fireplace...
Face Header. Example 1: Face of Fireplace Flush with Wall Framing. Stone, Tile or Brick Mortar Heavy Expanded Metal Non-Combustible Top View Material Example 2: Face of Fireplace Flush with Non-Combustible. Top View FPI FP90 Wood Fireplace...
Side to be a snug fi t in order to prevent it from Panel falling out when a fi re is burning. Panel Insulation Brick Bottom Vermiculite FPI FP90 Wood Fireplace...
fi rebox and add thumbscrews to secure in place. 6) Slide the ash drawer into the ash drawer shelf. 7) Place the lid and the ash plug tool on the fan trasfer plate for storage. FPI FP90 Wood Fireplace...
NEUTRAL - FROM FAN GROUND 910-896 THERMODISC 910-142 VARIABLE SWITCH 910-330 60T12 Diagram 2 6) Slide the fan transfer tray back into the unit and hook up wires to the Control Box and mount the thermo disc in place. FPI FP90 Wood Fireplace...
SO THAT THE 3/4" (19mm) FLANGES ARE ON THE INSIDE OF THE OPENING. SLOTTED HOLES ON RIGHT SIDE ONLY 43.000" (1092mm) NOTE: ONCE THE TEMPLATE IS MOUNTED CHECK TO MAKE SURE THE SIDES ARE PLUMB AND 43" (1092mm) IN WIDTH FPI FP90 Wood Fireplace...
Page 24
TO PREVENT MASONRY FACING MATERIAL FROM HITTING THE TOP STIFFENER LOCATED ON THE BACK OF THE SURROUND WHICH IS HIGHER THAN THIS EDGE. INSTALL THE SURROUND TEMPLATE ONTO THE UNIT WITH THE SAME MOUNTING SCREWS AS THE SURROUND. FPI FP90 Wood Fireplace...
fl ush with the face of the unit and allow the trim to be installed correctly (refer to Diagram 1). Front Trim Side Side Trim Trim Unit With Finished Trim Diagram Assembly De tails FPI FP90 Wood Fireplace...
Page 26
8) It is recommended that the joints of the sheathing run horizontal from the top corners of the unit rather than vertical. This will reduce the heat exposure to the joints and reduce the chance of the fi nish from cracking. FPI FP90 Wood Fireplace...
fi rebox fl ange. Slide downwards until the cross braces are resting on the fi rebox fl anges. 2) Fasten the handles to the screen using the fasteners provided. Front View Side View 3) Install fi rescreen. Side View FPI FP90 Wood Fireplace...
NOTE: Take care not to scratch the paint on the front of the fi replace when installing the top louver. Bottom Louver Frame Rotation Pin Tab (x2) Top Louver Mounting Tab (x2) Bottom Louver Rotation Pin Tab (x2) Diagram 2 Diagram 1 Bottom Louver Mounting Sequence FPI FP90 Wood Fireplace...
Re-install faceplate with plated screws. Place the emblem over the emblem design on the sur- round. Insert the studs through the holes. To secure them fi rst put on the split lock washer and then the nut and tighten. FPI FP90 Wood Fireplace...
DO NOT install a damaged kit. Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit. FPI FP90 Wood Fireplace...
Round Air Duct: Attach the 6" round air duct (supplied) to the fireplace collar and run the duct to the fan housing. Attach the round-to-oval adaptor to the fan housing and the air duct to the adaptor. FPI FP90 Wood Fireplace...
If creosote your draft control down to keep the fi re at a away from the unit while in use. has accumulated it shall be removed to moderate level. reduce the risk of a chimney fi re. FPI FP90 Wood Fireplace...
Do not substitute materials. If your glass door Grease door hinges with high temperature breaks, do not use your unit until it has been grease regularly for smooth operation and to replaced. avoid squeaks. FPI FP90 Wood Fireplace...
Rope Gasket 5/8 Med Desnity 001-551 Door Handle Assembly Complete - Right Tape 7/8 Window Adhesive 001-137 Steel Handle - Left Door 936-243 936-299 Tape 3/16 X 3/8in. 001-138 Steel Handle - Right Door 001-147F Anchor Bracket - Left Handle FPI FP90 Wood Fireplace...
At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.