P33 Gas Fireplace
FPI Direct Vent System (Flex)
Horizontal Terminations Only
This venting system, in combination with the P33 Direct Vent Gas
Fireplace, have been tested and listed as a direct vent heater system by
Warnock Hersey. The location of the termination cap must conform to the
requirements in the Vent Terminal Locations diagram, see manual.
FPI Direct Vent (Flex) System Termination Kits include all the parts
needed to install the P33 using a fl exible vent.
FPI Kit #
Length
Contains:
#946-513
2 Feet
1)
6-5/8" fl exible liner (Kit length)
2)
4" fl exible liner (Kit length)
3)
spring spacers (3)
4)
thimble (2)
#946-515
4 Feet
5)
AstroCap termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
#946-516
10 Feet
8)
plated screws (8)
9)
S.S. screws #8 x 1-1/2" drill point, (4)
Notes:
1)
Liner sections should be continuous without any joints or seams.
2)
Only Flex pipe purchased from Regency may be used for Flex
installations.
3)
Horizontal sections must be supported every 3 feet.
Wall Thimble (2 pc)
4" (102mm)
dia. flue pipe
6-7/8"
(173mm)
dia. Flue pipe
If required by the external termination location the listed
alternate termination caps may be used.
32
AstroCap
TM
Termination Cap
(Part# 946-523/P)
spring
spacer
Alternate Horizontal
Termination Caps
Gas Fireplaces
Important
When installing Cabinet Mantels: the wall thimble must be secured
fi rst and venting must be attached to unit before sliding into fi nal
position.

Snorkel Terminations

Snorkel Terminations:
For installations requiring a vertical rise on the exterior of the building,
14-inch and 36-inch tall Snorkel Terminations and the Riser Vents are
available. Follow the same installation procedures as used for standard
Horizontal Termination. NEVER install the snorkel upside down.
Dura-Vent
Snorkel
Min. 12"*
(305mm)
Below Grade Snorkel Installation (Dura-Vent Only)
If the Snorkel Termination must be installed below grade, i.e. basement
application, proper drainage must be provided to prevent water from
entering the Snorkel Termination. Refer to Rigid Pipe Installation
instructions for details. Do not attempt to enclose the Snorkel within the
wall, or any other type of enclosure.
August 2008 Product Specifi cations Book
Riser Vent
Termination
Min. 6-1/4"*
(159mm)
Dura-Vent
Snorkel
Window
Well
Adequate
drainage
Gravel