7
Check Your Setup
If your device is connected and configured correctly, you
will see the following LED Status:
COMM:
Red / Blinking Red
LINK:
Green
POST:
Green
POWER: Blue
8

Troubleshooting

LED
Color
Airborne Device State
Off
Adapter is not powered.
POWER
Blue
Adapter is powered.
Off
Adapter is not powered.
Adapter failed Power On Self Test ("POST") and is not configured for
Red
wireless communication.
POST
Adapter passed POST but is not configured for wireless network
Amber
communication.
Green
Adapter passed POST and is configured for wireless communication.
Adapter is not powered.
Off
(Periodic Blinking) Adapter is searching for a valid network
Red / Off
LINK
(Access Point) that matches device's configuration.
Green
Adapter has successfully associated with an Access Point.
If Power LED is also Off, then Adapter is not powered.
Off
If Power LED is On then, No TCP session from WLAN or Ethernet
interface has been established.
COMM
Red /
Blinking
A TCP connection has been established.
Red
Document Number: 710-11429-00_R0_ABDx-ER-IN50xx_0817qsg
Recommended Accessories
Model MDR-20-24
120VAC/5VDC Power Supply
or
Model PS-WDS
Power Supply with Appropriate
Cord (North America, EU, UK)
Model C5UMB10FBG
Ethernet Cable
1-888-948-2248 | Europe: +353 91 792444
advantech-bb.com
707 Dayton Road | PO Box 1040 | Ottawa, IL 61350
Phone: 815-433-5100 | Fax: 815-433-5109
www.advantech-bb.com | E-mail: support@advantech-bb.com

QUICK START

GUIDE
ABDN-ER-IN501x
Industrial Wireless Ethernet Bridge/Router
Before you begin, be
sure you have the following:
+ Wireless Ethernet Bridge/Router Product
(ABDN-ER-IN5010 or ABDN-ER-IN5018)
+ CD with Airborne Management Center
Software
+ 50 Ohm, omni-directional antenna
+ 5-36 VDC power for terminal block or a 5
VDC power supply (not included)
www.advantech-bb.com
Fast and easy on the web:

Advertisement

loading

Summary of Contents for B+B SmartWorx ABDN-ER-IN501 Series

  • Page 1: Quick Start

    (Continued) Check Your Setup QUICK START If your device is connected and configured correctly, you GUIDE will see the following LED Status: COMM: Red / Blinking Red LINK: Green POST: Green POWER: Blue Troubleshooting Color Airborne Device State Adapter is not powered. POWER Blue Adapter is powered.
  • Page 2: Product Overview

    CD or download and install it from restart the device. You can optionally press ‘Reload’ if you have the B+B SmartWorx website. Just search for the model further configuration changes to make. number and follow the links to download software from the Downloads section of the product page.