Website www.advantech-bb.com c 2018 Advantech B+B SmartWorx s.r.o. No part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photography, recording, or any information storage and retrieval system without written consent. Information in this manual is subject to change without notice, and does not represent a commitment on the part of Advantech B+B SmartWorx.
Page 3
Source codes under GPL licence are available free of charge by sending an email to: techSupport@advantech-bb.com. Please see http://ep.advantech-bb.cz/devzone for more information. Advantech B+B SmartWorx s.r.o., Sokolska 71, 562 04 Usti nad Orlici, Czech Republic Document No. MAN-0005-EN, revision from June 27, 2018. Released in the Czech Republic.
SmartFlex SR300 1. Safety Instructions Please, observe the following instructions: 1.1 Hazardous Locations Installation Instructions These devices are open-type devices that are to be installed in an enclosure suitable for the environment and can only be accessed with the use of a tool or key.
SmartFlex SR300 1.2 Other Safety Instructions The router must be used in compliance with all applicable international and national laws and in compliance with any special restrictions regulating the utilization of the router in prescribed applications and environments. To prevent possible injury and damage to appliances and to ensure compliance with all relevant provisions, use only the original accessories.
SmartFlex SR300 2. Product Disposal Instructions The WEEE (Waste Electrical and Electronic Equipment: 2012/19/EU) directive was in- troduced to ensure that electrical/electronic products are recycled using the best available recovery techniques in order to minimize impact on the environment. This product contains high quality materials and components which can be recycled.
Host port, two binary inputs and one output (I/O connector). An integral part of the router is also a memory card reader placed on the rear panel. This reader allows SmartFlex SR300 to operate with microSD cards and increase storage space of the router up to 64 GB (32 GB in case of SDHC cards).
SmartFlex SR300 4. Contents of Package Basic delivered set of router includes: router, power supply, crossover UTP cable, 2.4 GHz WiFi antenna (only for version with WiFi), loose power and I/O connector (+8 pins ), clip for the DIN rail, paper start guide.
5. Router Design 5.1 Router versions SmartFlex SR300 router is supplied in the following versions (see table below). All versions are available in plastic or metal box according to customer requirements. All versions are available with PoE PD (Power over Ethernet – powered device) so you can power the router from both ETH0 and ETH1 interfaces, or with PoE PSE (power source equipment) so you can power other devices by the router.
SmartFlex SR300 5.2 Delivery identification Trade name Product name Description SmartFlex SR300 SmartFlex Router in a plastic or metal box Table 2: Delivery identification Figure 6: Label examples 5.3 Order codes Order codes overview is shown in the table below.
SmartFlex SR300 Letter "y" – type of the router box Type of box Number "y" in code Plastic Metal Table 5: Type of router box Letter "z" – type of the power supply connector Type of power supply Number "z" in code Europe UK &...
SmartFlex SR300 5.4 Basic dimensions of the router box Figure 7: Basic dimensions of the router box 5.5 Mounting recommendations Possibility to be put on a work surface, DIN rail EN 60715 with included plastic or metal clip. For the most of applications with a built-in router in a switch board it is possible to recognize...
SmartFlex SR300 Sufficient space must be left before individual connectors for handling of cables, For correct function of the router we recommend to use in the switch-board earth-bonding distribution frame for grounding of power supply of router, data cables and antenna.
SmartFlex SR300 5.7 Description of the rear panel The rear panel contains only one holder for SD card (SD) and RST button used to restore default configuration and reboot the router. 5.8 Description of the front panel On the front panel is the following:...
SmartFlex SR300 5.8.1 Status indication About router status inform nine LED indicators on the front panel. Each ETH port has two additional LEDs that provide information about port status. Caption Color State Description Green Blinking Router is ready Starting of the router Fast blinking Updating firmware...
SmartFlex SR300 5.8.2 Power connector PWR Panel socket 2-pin. Pin number Signal mark Description GND(-) Negative pole of DC supply voltage VCC(+) Positive pole of DC supply voltage (+10 to +60 V DC) Table 10: Connection of power connector Figure 11: Power connector Unit has to be supplied by a power supply specified as a Limited Power Source (LPS) ac-...
SmartFlex SR300 5.8.3 Antenna connector WiFi If the router is equipped with WiFi module on the customer’s request, appropriate antenna is connected to the reverse SMA connector (WiFi). The extarnal antenna is connected by screwing this antenna to the reverse SMA connector on the front panel of the router (see figure below).
SmartFlex SR300 5.8.4 MicroSD card reader The microSD card reader is placed on the rear panel of the router (there is only a single slot). This card reader allows the router to operate with memory cards microSD. Technical specifications are stated in the table below.
SmartFlex SR300 5.8.5 Ethernet Ports (ETH0 and ETH1) Panel socket RJ45. Signal mark Description Data flow direction TXD+ Transmit Data – positive pole Input/Output TXD- Transmit Data – negative pole Input/Output RXD+ Receive Data – positive pole Input/Output PoE power + (if it’s equipped by PoE) PoE power + (if it’s equipped by PoE)
SmartFlex SR300 5.8.6 Power over Ethernet (PoE) On the router models with PoE, the PoE+ standard IEEE 802.3at-2009 and PoE standard IEEE 802.3af-2003 are supported in both Ethernet ports (ETH0, ETH1). The PoE PD version allows the router to be powered over the Ethernet by another PoE PSE device. The PoE PSE version also allows the router to power other devices over the Ethernet.
SmartFlex SR300 PoE PSE Figure 18: PoE PSE usage The power supply used with the PoE PSE router has to provide voltage from 44 to 57 V DC and the output power has to be at least 65 W for full PoE+ use (Class 4) in both Ethernet ports (ETH0 and ETH1).
SmartFlex SR300 5.8.7 USB Port Panel socket USB-A. Signal mark Description Data flow direction +5 V Positive pole of 5 V DC supply voltage, 0.5 A USB data - USB data signal – negative pole Input/Output USB data + USB data signal – positive pole...
SmartFlex SR300 5.8.8 I/O Port Panel socket 6-pin. Signal mark Description Binary input 0 Binary input 0 Binary input 1 Binary input 1 Binary output Binary output Table 15: Connection of I/O port Figure 20: I/O connector The I/O user Interface is designed for the processing of binary input and control (setting) of binary output.
SmartFlex SR300 Binary inputs connection example: Figure 21: Binary inputs connection Binary output Binary output parameters: – 60 V AC / 300 mA – 60 V DC / 300 mA The current of the binary output is limited by a resettable fuse (300 mA).
SmartFlex SR300 5.8.9 Reset When PWR LED starts flashing on the front panel, it is possible to restore the default con- figuration of the router by pressing the RST button on the rear panel. After pressing this button the default configuration is restored and then router reboots (green LED will be on).
SmartFlex SR300 5.9 Interfaces Description There are available versions with one of the following interfaces: SWITCH interface 5.9.1 SWITCH interface Three LAN ports of SWITCH interface for SmartFlex routers (RJ45 connectors for connect- ing Ethernet devices) act as a typical switch device. This means that the router reads Ethernet frames (data packets on an Ethernet link) from any port on SWITCH interface and transmits them on other ports of the SWITCH interface.
SmartFlex SR300 6. First Use 6.1 Connecting the router before first use Before putting the router into operation it is necessary to connect all components which are required to run your applications. The router can not operate without connected power supply.
SmartFlex SR300 6.2 Start The router is put into operation when the power supply is connected to this router. By default, the router will automatically start to log on to the default APN. DHCP server will start to assign addresses for devices on the Ethernet port ETH0. Router behavior can be changed via the web interface.
SmartFlex SR300 After successfully entering login information user gains access to the router via his internet browser. Figure 28: Router web interface A detailed description of the router settings via the Web interface can be found in the document Configuration manual for SmartFlex routers.
SmartFlex SR300 7. Technical Parameters 7.1 Basic parameters SmartFlex SR300 Temperature range Operating -40 C to +80 C Storage -40 C to +85 C Cold start -40 C Humidity Operating 0 to 95 % relative humidity non condensing Storage 0 to 95 % relative humidity non condensing...
SmartFlex SR300 7.2 Standards and regulations The router complies with the following standards and regulations: Standards and regulations Radio ETSI EN 300 328 V2.1.1, ETSI EN 301 893 V2.1.1 ETSI EN 301 489-1 V1.9.2, ETSI EN 301 489-1 V2.1.1, ETSI EN 301 489-17 V3.1.1...
SmartFlex SR300 7.3 Type tests and environmental conditions Phenomena Test Description Test levels EN 61000-4-2 Enclosure contact 6 kV (crit. A) Enclosure air 8 kV (crit. A) RF field AM EN 61000-4-3 Enclosure 20 V/m (crit. A) modulated (80 – 2700 MHz) 3 V/m (crit.
SmartFlex SR300 7.6 Technical Parameters of Power over Ethernet (PoE) Standards IEEE 802.3at-2009 (PoE+) and IEEE 802.3af-2003 (PoE) are supported. Ca- bling needed is Category 5, up to 12.5 . It is possible to use a passive PoE injector. PoE PD: parameters for opposite PSE Input voltage range 42.5 –...
SmartFlex SR300 9. Troubleshooting If you cannot connect to the router from your PC, your network card may be configured in such a way that it is not possible to connect to the router. Take one or more of the following steps in order to solve the problem: Make sure your PC’s network card is configured to obtain the IP address form the...
Page 41
SmartFlex SR300 You can verify a Firewall by accessing remotely to the router’s Web interface. The operator may not provide the address of DNS server and without DNS server’s address it is impossible to connect to the dyndns.org server. The following mes- sages will be shown in the System Log: –...
During cleaning of the router do not use aggressive chemicals, solvents and abrasive cleaners! Hereby, Advantech B+B SmartWorx s.r.o. company declares that the radio equipment narrated in this user’s guide is in compliance with EU Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address:...