RT510 & RT510RF Quick Guide
Introduction
The RT510 thermostat will switch your heating system on or off, as needed, in accordance with the temperature set
by you. The RT510 series includes the following products:
• RT510 for wired applications
• RT510RF (RT510TX + RXRT510) for wireless applications
• RT510TX for wireless application, using 5 x 5 receiver
• RXRT510 for wireless application using 5 x 5 transmitter
• RT510BC for wireless application
Go to www.salus-manuals.com for the full PDF version of the manual.
Product Compliance
EU Directives: 2014/53/EU and 2011/65/EU. Please check www.saluslegal.com for the full information.
868.0-868.6MHz; <13dBm
Safety Information
Use in accordance with the EU and national regulations. For indoor use only.
Keep your device completely dry. This product must be installed by a competent person and in accordance with all
the EU and national regulations.
Always isolate the AC Mains supply before installing or working
on any components that require 230 VAC 50Hz supply.
Installation
RT510 Thermostat
1
+Hr
Insert the batteries and
SELECT
SET
wire up the device.
Terminal
Description
Backplate
1 (COM)
Common Terminal
2 (NC)
Switched Live OFF
3 (NO)
Switched Live ON
Installation
RT510RF (RT510TX+RXRT510)Thermostat and Receiver
1. Wire up the receiver and switch the power on
2. Once the receiver is switched on then insert the batteries into the
thermostat. If using RT510RF pack the devices are already paired.
Now follow Test pairing process to confirm connection between both the
thermostat and receiver. If purchased the devices separately please follow
pairing process.
After power up, the
receiver will be in
pairing mode and
the LED will flash red.
ON
OFF
AUTO
MANUAL
Remove the link wire in the boiler
Terminal
Description
NO
Switch Terminal
COM
Common Switch Terminal
L
Mains Live (230VAC)
N
Mains Neutral
RT510BC (RT510TX+Boiler Controller)
1
+Hr
TEST / PAIRING
SELECT
SET
Wire up the boiler controller and switch it ON. After that please insert the
batteries into the thermostat.
Leave the link wire in the boiler
Terminal
Description
1 (N)
Mains Neutral
2 (L)
Mains Live
RESET
3 (COM)
Common Switch Terminal
4 (NO)
Switch Terminal
Dip Switch Settings
The DIP switches are found on the rear of
your thermostat and can be used to change
the span (temperature accuracy) of your
thermostat from the default +/-0.5°C to
+/-0.25°C and the programmes 5-2 or 24h.
Changing DIP Switch 2 may cause your boiler
to operate more frequently. The DIP switches
are located on the back of the thermostat.
Button Functions RT510 and RT510TX
RT510
1
+Hr
RESET
SELECT
SET
1
+Hr
SELECT
SET
TEST / PAIRING
Key
Function
1. Press once to activate Frost Mode
2. Press for 3 seconds in order to activate Holiday Mode.
+Hr
Press once to activate/deactivate Boost function
Press once to enter/exit Permanent Override function.
Receiver Terminals
Increase button
Decrease button
Select the clock or programme settings
NO
COM
L N
SELECT
Press to confirm your settings
SET
1. Press once to enter in Test Mode for RT510RF
2. Press for 3 seconds to enter/exit Pairing Mode for RT510RF
3. Press once to return to Factory Settings for the RT510
+
+
Press the buttons for 3 seconds to enter Installer Mode
SELECT
+
Press the buttons for 3 seconds to enter Clock Settings
SET
Installer Mode
1
+Hr
RESET
SELECT
SET
3 Sec
3 Sec
Plug in BC terminals
6
5
4
3
2
1
L
N
4
3
2
1
L
N
Press the three buttons
4
3
2
1
together for 3 seconds.
6
5
4
3
2
1
L
N
4
3
2
dxx
Function
Parameter
ON
24H
+/-0.25
Temperature display
d01
0.1 or 0.5°C
increments
d02
Temperature offset
+/-3.0°C
5-2
+/-0.5
d03
Frost setpoint
5.0-17.0°C Set the Frost Point temperature 5.0°C
1
2
Pairing the RT510TX with the Receiver/Boiler Controller
RT510TX
If you are using the RT510RF or RT510BC pack, the pairing between
the thermostat and the receiver/boiler controller is already done.
If you bought an RT510TX and RXRT510 separately then pair as follows.
1
+Hr
Please make sure that the Receiver/Boiler Controller is set on Auto.
Begin the pairing process
TEST / PAIRING
SELECT
SET
+Hr
End the pairing process
+Hr
Test the pairing process
+Hr
+Hr
If you bought an RXRT510 or RT510TX and intend pairing with other
devices in the 5x5 range, please refer to the Receiver Units manual, or the
3 Sec
relevant manuals available at www.salus-manuals.com
+Hr
Button Description for RXRT510 Receiver
Button
RESET
SELECT
SET
ON
OFF
AUTO
MANUAL
1
L
N
Button Description for RXBC605 Boiler Controller
Description
Default
value
Button
Select temperature display
SYNC
0.5°C
increments
Calibrate your thermostat
AUTO
0.0°C
temperature
MANUAL
1
+Hr
3 Sec
TEST / PAIRING
TEST / PAIRING
SELECT
SET
SELECT
SET
Wait 9 minutes for the timeout
process to be complete.
1
+Hr
3 Sec
TEST / PAIRING
TEST / PAIRING
SELECT
SET
SELECT
SET
ON
OFF
1
AUTO
MANUAL
SELECT
SET
TEST / PAIRING
ON
OFF
AUTO
MANUAL
TEST / PAIRING
SELECT
SET
Function
The receiver is enabled, ready for use.
The receiver is disabled, will not function.
ON
OFF
The receiver will switch on and off automatically,
as operated by the thermostat.
AUTO
MANUAL
Providing ON is selected,the receiver will switch
on continuously, overriding the thermostat.
Function
The boiler controller will be syncronised with the
thermostat.
The receiver will switch on and off automatically,
as operated by the thermostat.
Select in the event of thermostat failure to switch
boiler on continuously, overriding the thermostat.